UNT Libraries Government Documents Department - 12,134 Matching Results

Search Results

open access

100-FR-3 groundwater/soil gas supplemental limited field investigation report

Description: In 1993, a Limited Field Investigation (LFI) was conducted for the 100-FR-3 Operable Unit which identified trichloroethylene (TCE) as a contaminant of potential concern (COPC) (DOE-RL 1994). In groundwater samples collected for the LFI, TCE was detected in well 199-177-1 at a concentration exceeding the U.S. Environmental Protection Agency (EPA) maximum contaminant level (5 {mu}g/L) and Washington State groundwater criteria (3 {mu}g/L). With the concurrence of the EPA and the Washington State D… more
Date: April 1, 1996
open access

A 100 MVA generator utilizing high temperature superconducting windings -- design assessment & component development. Final report

Description: The operation of a high temperature superconducting generator rotor using closed-cycle refrigeration to indirectly cool the field windings was considered to be the best choice for an HTS application. The SPI program proposed to achieve the following goals: In Task 1 a 100 MVA generator with a HTS rotor field winding would be designed. An energy and economic benefits analysis was to be a key part of the program. In addition, the generator/grid interactions were to be modeled. Concurrently, Task … more
Date: November 1, 1996
Creator: Lay, K.
open access

105-DR Large Sodium Fire Facility closure activities evaluation report

Description: This report evaluates the closure activities at the 105-DR Large Sodium Fire Facility. The evaluation compares these activities to the regulatory requirements and closure plan requirements. The report concludes that the areas identified in the closure plan can be clean closed. This report summarizes and evaluates the closure activities performed in support of partial closure of the 105-DR Large Sodium Fire Facility (LSFF). This evaluation will be used in assessing the condition of the 105-DR LS… more
Date: April 11, 1996
Creator: Adler, J. G.
open access

105-DR Large Sodium Fire Facility closure activities evaluation report

Description: This report evaluates the closure activities at the 105-DR Large Sodium Fire Facility. The closure activities discussed include: the closure activities for the structures, equipment, soil, and gravel scrubber; decontamination methods; materials made available for recycling or reuse; and waste management. The evaluation compares these activities to the regulatory requirements and closure plan requirements. The report concludes that the areas identified in the closure plan can be clean closed.
Date: April 22, 1996
Creator: Adler, J. G.
open access

105-DR Large sodium fire facility soil sampling data evaluation report

Description: This report evaluates the soil sampling activities, soil sample analysis, and soil sample data associated with the closure activities at the 105-DR Large Sodium Fire Facility. The evaluation compares these activities to the regulatory requirements for meeting clean closure. The report concludes that there is no soil contamination from the waste treatment activities.
Date: January 23, 1996
Creator: Adler, J. G.
open access

105 K east ion exchange and cartridge filter restart instrumentation acceptance test report

Description: Acceptance Test Report following the completion of ATP-012 for the 105KE CP-A and CP-A Computer and PLC Panels. The test was conducted from 11/13/95 to 12/11/95. Three test discrepancies were generated during the ATP and all were dispositioned and closed. All sections were completed except Section 5.9 which was deleted per ECN 190556.
Date: January 8, 1996
Creator: Whitehurst, R.
open access

105-K east sandfilter backwash line sample analysis report. Second campaign

Description: This project seeks to produce uranium (U) and plutonium (Pu) analyses of samples taken from the KE basin filter backwash line each time the sand filter is backwashed. K Basin operations will use the analytical results to determine additions of fissile materials to the backwash sludge pit and thereby maintain a running inventory of fissile elements in the pit. K Basin Operations must not exceed a certain total inventory in order to be within a criticality specification. The second campaign of th… more
Date: January 25, 1996
Creator: Miller, George L.
open access

105-K east sandfilter backwash line sample analysis report: Third campaign

Description: This project seeks to produce uranium (U) and plutonium (Pu) analyses of samples taken from the KE basin filter backwash line each time the sand filter is backwashed. K Basin operations will use the analytical results to determine additions of fissile materials to the backwash sludge pit and thereby maintain a running inventory of fissile elements in the pit. K Basin operations must not exceed a certain total inventory in order to be within a criticality specification. The third campaign of thi… more
Date: January 25, 1996
Creator: Miller, George L. & Bechtold, D. B.
open access

125 TON MPC WASTE PACKAGE SHIELDING ANALYSIS/2-D DORT (SCPB: N/A)

Description: This analysis is prepared by the Mined Geologic Disposal System (MGDS) Waste Package Development Department (WPDD) to determine the dose rates from the MPC waste packages to be used by the EBS and other repository systems to incorporate ALARA practices in the overall repository design in compliance with the goals of the Waste Package Implementation Plan for conceptual design. These design calculations are performed in sufficient detail to provide a comprehensive comparison base with other desig… more
Date: February 26, 1996
Creator: Skulina, D. J.
open access

150-MW S-band klystron program at the Stanford Linear Accelerator Center

Description: Two S-Band klystrons operating at 150 MW have been designed, fabricated and tested at the Stanford Linear Accelerator Center (SLAC) during the past two years for use in an experimental accelerator at Deutsches Elektronen-Synchrotron (DESY) in Hamburg, Germany. Both klystrons operate at the design power, 60 Hz repetition rate, 3 {micro}s pulsewidth, with an efficiency {gt} 40%, and agreement between the experimental results and simulations is excellent. The 535 kV, 700 A electron gun was tested … more
Date: July 1, 1996
Creator: Sprehn, D.; Caryotakis, G. & Phillips, R. M.
open access

200 Area population weighted X/Q for the public within 10 miles of the site boundary

Description: An overall population weighted atmospheric dispersion coefficient (X/Q) has been calculated for the public within 10 miles of the Hanford Site boundary. The Columbia river was assumed as the Hanford site boundary to the north and the east. The GXQ code was used for the calculation. The value calculated is 1.88 x 10-8 s/m 3.
Date: July 9, 1996
Creator: Van Keuren, J.C., Westinghouse Hanford
open access

200-BP-5 operable unit treatability test report

Description: The 200-BP-5 Operable Unit was established in response to recommendations presented in the 200 East Groundwater Aggregate Area Management Study Report (AAMSR) (DOE-RL 1993a). Recognizing different approaches to remediation, the groundwater AAMSR recommended separating groundwater from source and vadose zone operable units and subdividing 200 East Area groundwater into two operable units. The division between the 200-BP-5 and 200-PO-1 Operable Units was based principally on source operable unit … more
Date: April 1, 1996
open access

222-S Analytical services final results for Tank 241-U-101, grab samples 1U-96-1 through 1U-96-4

Description: This document is the final, format IV, laboratory report for characterization of tank 241-U-101 (U-101) grab samples from risers 1 and 7. It transmits additional analytical data for specific gravity (Sp.G.), and all raw analytical data which were not provided in the 45-day report. The 45-day report is attached to this final report as Part II. Secondary analyses were not performed on any of the U-101 samples. This is because none of the primary analyte limits, which trigger the performance of se… more
Date: August 23, 1996
Creator: Miller, G. L.
open access

225-B ion exchange piping design documentation

Description: This document describes the interface between the planned permanent ion exchange piping system and the planned portable ion exchange system. This is part of the Waste Encapsulation and Storage Facility (WESF). In order to decouple this WESF from B-Plant and to improve recovery from a capsule leak, contaminated pool cell water will be recirculated through a portable ion exchange resin system.
Date: February 1, 1996
Creator: Prather, M. C.
open access

225-B Pool Cell 5 Liner Leak Investigation

Description: This document describes the actions taken to confirm and respond to a very small (0.046 ml/min) leak in the stainless steel liner of Hanford`s Waste Encapsulation and Storage Facility (WESF) storage pool cell 5 in Building 225-B. Manual level measurements confirmed a consistent weekly accumulation of 0.46 liters of water in the leak detection grid sump below the pool cell 5 liner. Video inspections and samples point to the capsule storage pool as the source of the water. The present leak rate c… more
Date: June 7, 1996
Creator: Rasmussen, J.H., Westinghouse Hanford
open access

242-A campaign 95-1 post run document

Description: The 242-A Evaporator Campaign 95-1 was started on June 6, 1995 and finished July 27, 1995. An overall Waste Volume Reduction (WVR) of 8.18 million liters (2.16 mGAL OR 87.6% WVRF) was achieved from 9.35 million liters (2.47 Mgal) of processable waste contained in 108-AP, 107-AP, 106-AW and 102-AW. Slurry generated from Campaign 95-1 consisted of 1.05 million liters (278,000 gal) of dilute double-shell slurry feed (DDSSF) with a SpG of approximately 1.34. Total process condensate discharged to L… more
Date: February 12, 1996
Creator: Guthrie, M.D.
open access

242-A Evaporator/plutonium uranium extraction (PUREX) effluent treatment facility (ETF) nonradioactive air emission test report

Description: This report shows the methods used to test the stack gas outlet concentration and emission rate of Volatile Organic Compounds as Total Non-Methane Hydrocarbons in parts per million by volume,grams per dry standard cubic meter, and grams per minute from the PUREX ETF stream number G6 on the Hanford Site. Test results are shown in Appendix B.1.
Date: May 10, 1996
Creator: Hill, J. S.
open access

300 Area dangerous waste tank management system: Compliance plan approach. Final report

Description: In its Dec. 5, 1989 letter to DOE-Richland (DOE-RL) Operations, the Washington State Dept. of Ecology requested that DOE-RL prepare ``a plant evaluating alternatives for storage and/or treatment of hazardous waste in the 300 Area...``. This document, prepared in response to that letter, presents the proposed approach to compliance of the 300 Area with the federal Resource Conservation and Recovery Act and Washington State`s Chapter 173-303 WAC, Dangerous Waste Regulations. It also contains 10 a… more
Date: March 1, 1996
Back to Top of Screen