Performance of the 2 MeV microwave gun for the SSRL 150 MeV linac

PDF Version Also Available for Download.

Description

As described in a previous article, the preinjector linac for SSRL's 3 GeV synchrotron is fed by a 2 MeV, 1.5 A, low-emittance microwave gun, consisting of a thermionic cathode mounted in the first cell of a 1-1/2-cell S-band cavity. In this article, we report on the successful operation of the low-emittance gun, the longitudinally-bunching alpha-magnet, and the three-microbunch FET-pulsed beam-chopper. Simulations predict a normalized rms emittance at the gun exit of less than 10 {pi}{center dot}m{sub e}c{center dot}{mu}m; chromatic effects in transport optics increase this to approximately 30 {pi}{center dot}m{sub e}c{center dot}{mu}m. The gun was specifically designed to have … continued below

Physical Description

14 pages

Creation Information

Borland, M.; Weaver, J. N.; Wiedemann, H. (Stanford Univ., CA (USA). Stanford Synchrotron Radiation Lab.); Green, M. C.; Nelson, L. V. (Varian Associates, Inc., Palo Alto, CA (USA)); Miller, R. H. (Stanford Linear Accelerator Center, Menlo Park, CA (USA)) et al. September 1, 1990.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 65 times. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

As described in a previous article, the preinjector linac for SSRL's 3 GeV synchrotron is fed by a 2 MeV, 1.5 A, low-emittance microwave gun, consisting of a thermionic cathode mounted in the first cell of a 1-1/2-cell S-band cavity. In this article, we report on the successful operation of the low-emittance gun, the longitudinally-bunching alpha-magnet, and the three-microbunch FET-pulsed beam-chopper. Simulations predict a normalized rms emittance at the gun exit of less than 10 {pi}{center dot}m{sub e}c{center dot}{mu}m; chromatic effects in transport optics increase this to approximately 30 {pi}{center dot}m{sub e}c{center dot}{mu}m. The gun was specifically designed to have a longitudinal phase-space suited to magnetic compression, as a result of which we predict that peak currents in excess of 300 A in a 1 ps bunch are feasible with the existing alpha-magnet. Results of simulations and experiments will be presented and compared. 13 refs., 9 figs.

Physical Description

14 pages

Notes

NTIS, PC A03/MF A01; OSTI; INIS; GPO Dep.

Source

  • Linear accelerator conference, Albuquerque, NM (USA), 9-14 Sep 1990

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Other: DE91004688
  • Report No.: SLAC-PUB-5333
  • Report No.: CONF-9009123--60
  • Grant Number: AC03-76SF00515
  • Office of Scientific & Technical Information Report Number: 6183102
  • Archival Resource Key: ark:/67531/metadc1111457

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • September 1, 1990

Added to The UNT Digital Library

  • Feb. 22, 2018, 7:45 p.m.

Description Last Updated

  • May 20, 2020, 11:47 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 65

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Borland, M.; Weaver, J. N.; Wiedemann, H. (Stanford Univ., CA (USA). Stanford Synchrotron Radiation Lab.); Green, M. C.; Nelson, L. V. (Varian Associates, Inc., Palo Alto, CA (USA)); Miller, R. H. (Stanford Linear Accelerator Center, Menlo Park, CA (USA)) et al. Performance of the 2 MeV microwave gun for the SSRL 150 MeV linac, article, September 1, 1990; Menlo Park, California. (https://digital.library.unt.edu/ark:/67531/metadc1111457/: accessed May 22, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen