Test Results on Bias Setting for the Chicago Scaler Offner Models
Description:
Abstract: The counting accuracy of the Chicago Scalers, Models 961A and 961B, is a function of the bias setting of the limiter (V2). this report gives quantitative data supporting this thesis. A method of making bias settings is suggested. These tests were run at the suggestion of Mr. V. C. Hanson.
Date:
September 11, 1944
Creator:
Bradley, Wendell H.; Epstein, Bernard. & Wakefield, Ernest