Summary: Tests with the two-rod assembly were performed with liquid film trippers attached to the unheated wall, and a variation in rod spacing. Experimental data and improved high-speed motion pictures have been obtained of transition boiling behavior. The changes of the local heat transfer process between nucleate and film boiling can be readily distinguished i the motion pictures. Observational test performed with very short fins on the heated surface resulted in essentially eliminating transition boiling temperature fluctuations and doubling the film boiling coefficient. These gains were attained without reduction of the critical heat flux
Summary: Transition boiling data was taken with an improved flow loop, to explore the influence of loop characteristics on rod temperature fluctuations the transition region was found to be much smaller than for comparable conditions with a different loop. Also the amplitude, and frequency of the temperature oscillations, were significantly less than before. These results indicate that loop characteristic and flow disturbance parameters play a prominent part in governing the transition temperature fluctuations. Additional two-rod transition boiling data are presented. The results include data taken at high wall temperature levels during a demonstration test at low steam qualities, and the effect of a change in rod spacing on heat transfer performance.