The Advanced Photon Source (APS) linac high-power switching system makes use of 340-size waveguide components. These components include vacuum-grade furnace-brazed transitions, pressurized-grade aluminum 340-size switches, and more recently 340-size ceramic windows. The fabrication of these 340-size windows proceeded with brazing of ceramic membrane to thin-walled copper sleeves and real-time network analyzer testing performed by the ASD (Accelerator Systems Division) RF (Radio Frequency) Group. Initially it was thought that this real-time testing of prototype hardware would be necessary in the investigative stage to establish the required dimensions and physical geometry to satisfy the 40-dB return-loss criteria. However, producing four windows now …
continued below
Publisher Info:
Argonne National Lab., IL (United States)
Place of Publication:
Illinois
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this article.
Follow the links below to find similar items on the Digital Library.
Description
The Advanced Photon Source (APS) linac high-power switching system makes use of 340-size waveguide components. These components include vacuum-grade furnace-brazed transitions, pressurized-grade aluminum 340-size switches, and more recently 340-size ceramic windows. The fabrication of these 340-size windows proceeded with brazing of ceramic membrane to thin-walled copper sleeves and real-time network analyzer testing performed by the ASD (Accelerator Systems Division) RF (Radio Frequency) Group. Initially it was thought that this real-time testing of prototype hardware would be necessary in the investigative stage to establish the required dimensions and physical geometry to satisfy the 40-dB return-loss criteria. However, producing four windows now installed involved real-time network analyzer testing during production of each window conducted in parallel with adjustments of tuners designed into each 340-size ceramic window.
2nd International Workshop on Mechanical Engineering Design of Synchrotron Radiation Equipment and Instrumentation (MEDSI 2002), Argonne, IL (US), 09/05/2002--09/06/2002
This article is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Berg, S.; Bromberek, D.; Goeppner, G.; Haase, A.; Hoyt, J.; Michalek, W. et al.Development of the low return loss 340-size ceramic window for the APS linac.,
article,
October 10, 2002;
Illinois.