Indoor ozone concentrations: Ventilation rate impacts and mechanisms of outdoor concentration attenuation

PDF Version Also Available for Download.

Description

The classification of outdoor (ambient) air as fresh for the purposes of ventilation is not always appropriate, particularly in urban areas. In many cities of the world, urban air frequently violates health-based air quality standards due to high ozone concentrations. The degree of protection from exposure to ozone offered by the indoor environment depends on the relationship between indoor and outdoor ozone levels. Existing concentration data indicates that indoor/outdoor ozone ratios range between 10 and 80%. This paper analyzes several of the key issues influencing indoor ozone concentrations, including: (1) the degree of penetration of outdoor ozone indoors, (2) removal … continued below

Physical Description

20 pages

Creation Information

Cano-Ruiz, J. A.; Modera, M. P. & Nazaroff, W. W. July 1, 1992.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Sponsors

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

The classification of outdoor (ambient) air as fresh for the purposes of ventilation is not always appropriate, particularly in urban areas. In many cities of the world, urban air frequently violates health-based air quality standards due to high ozone concentrations. The degree of protection from exposure to ozone offered by the indoor environment depends on the relationship between indoor and outdoor ozone levels. Existing concentration data indicates that indoor/outdoor ozone ratios range between 10 and 80%. This paper analyzes several of the key issues influencing indoor ozone concentrations, including: (1) the degree of penetration of outdoor ozone indoors, (2) removal within the indoor environment (removal at surfaces and within air distribution systems), and (3) the correlation in time between outdoor ozone levels and ventilation rates. A model for calculating the degree of ozone removal in typical building leaks and air distribution systems is described and applied to a range of typical cases. This model indicates that the degree of removal is minimal for most wooden building cracks, but could be significant in leaks in concrete or brick structures, and is strongly dependent on the lining material for air distribution systems. Indoor ozone exposure estimates based on hourly outdoor ozone monitoring data and hour-by-hour weather-based simulations of infiltration rates and building operation are reported for a few residential scenarios. These estimates serve as a basis for exploring the impact of energy-efficient ventilation strategies on indoor ozone exposures.

Physical Description

20 pages

Notes

OSTI; NTIS; GPO Dep.

Source

  • 13. air infiltration and ventilation conference: ventilation for energy efficiency and optimum indoor air quality, Nice (France), 15-18 Sep 1992

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Other: DE93000633
  • Report No.: LBL-32639
  • Report No.: CONF-9209236--1
  • Grant Number: AC03-76SF00098
  • Office of Scientific & Technical Information Report Number: 7184816
  • Archival Resource Key: ark:/67531/metadc1447156

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • July 1, 1992

Added to The UNT Digital Library

  • Feb. 10, 2019, 8:45 p.m.

Description Last Updated

  • Jan. 14, 2020, 6:42 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Cano-Ruiz, J. A.; Modera, M. P. & Nazaroff, W. W. Indoor ozone concentrations: Ventilation rate impacts and mechanisms of outdoor concentration attenuation, article, July 1, 1992; California. (https://digital.library.unt.edu/ark:/67531/metadc1447156/: accessed June 12, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen