The 470 Ohm carbon resistor gauge has been used in the stress range up to approximately 4-5 GPa for highly heterogeneous materials and/or divergent flow experiments. The attractiveness of the gauge is due to its rugged nature, simple construction, low cost, reproducibility, and survivability in dynamic events. The associated drawbacks are a long time response to pressure equilibration and gauge resistance hysteresis. In the range below 0.4 GPa, the gauge calibration has been mainly extrapolated into this regime. Because of the need for calibration data within this low stress regime, calibration experiments were performed using a split-Hopkinson bar, drop tower …
continued below
Publisher Info:
Lawrence Livermore National Lab., CA (United States)
Place of Publication:
California
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this article.
Follow the links below to find similar items on the Digital Library.
Description
The 470 Ohm carbon resistor gauge has been used in the stress range up to approximately 4-5 GPa for highly heterogeneous materials and/or divergent flow experiments. The attractiveness of the gauge is due to its rugged nature, simple construction, low cost, reproducibility, and survivability in dynamic events. The associated drawbacks are a long time response to pressure equilibration and gauge resistance hysteresis. In the range below 0.4 GPa, the gauge calibration has been mainly extrapolated into this regime. Because of the need for calibration data within this low stress regime, calibration experiments were performed using a split-Hopkinson bar, drop tower apparatus, and a gas pressure chamber. Since the performance of the gauge at elevated temperatures is a concern, the change in resistance due to heating at atmospheric pressure was also investigated. Details of the various calibration arrangements and the results will be discussed and compared a calibration curve fit to previously published calibration data.
This article is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Cunningham, B; Vandersall, K S; Niles, A M; Greenwood, D W; Garcia, F & Forbes, J W.Carbon Resistor Pressure Gauge Calibration at Low Stresses,