Artificial cooling of the Columbia River by dam regulation, 1960

PDF Version Also Available for Download.

Description

This report discusses benefits in an increase in the flow of water from the lower depths of the Grand Coulee Dam which was used to lower river temperature at HAPO. A net average daily reduction of over 1.2{degree}C resulted at HAPO with a peak of 2.7{degree}C. The Net Production gain from temperature change was 6910 MWD and the Cost of Control was: Grand Coulee Charges $3,120.00, and other (Estimated) 6,880.00 for a total of $10,00.00.

Physical Description

11 p.

Creation Information

Kramer, H. A. February 15, 1961.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Sponsor

Publisher

  • Hanford Atomic Products Operation
    Publisher Info: General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
    Place of Publication: Richland, Washington

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This report discusses benefits in an increase in the flow of water from the lower depths of the Grand Coulee Dam which was used to lower river temperature at HAPO. A net average daily reduction of over 1.2{degree}C resulted at HAPO with a peak of 2.7{degree}C. The Net Production gain from temperature change was 6910 MWD and the Cost of Control was: Grand Coulee Charges $3,120.00, and other (Estimated) 6,880.00 for a total of $10,00.00.

Physical Description

11 p.

Notes

OSTI as DE94007808; Paper copy available at OSTI: phone, 865-576-8401, or email, reports@adonis.osti.gov

Source

  • Other Information: PBD: 15 Feb 1961

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • February 15, 1961

Added to The UNT Digital Library

  • Nov. 3, 2018, 11:47 a.m.

Description Last Updated

  • Nov. 19, 2018, 8:18 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 4

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Kramer, H. A. Artificial cooling of the Columbia River by dam regulation, 1960, report, February 15, 1961; Richland, Washington. (https://digital.library.unt.edu/ark:/67531/metadc1315832/: accessed July 16, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen