Shielding calculations were performed for the DIII-D facility at La Jolla to independently assess the biological dose from radiation emitted during operation. These calculations for both the fully shielded and bare configurations are in essential agreement with those done by General Atomics. In addition to the basic test problems run by General Atomics, a bare configuration with additional air outside the facility area was calculated. The addition of air to the bare configuration caused the dose at 100 meters from the DIII-D center-line to increase by fifty-five percent. The inclusion of the various elemental constituents in the soil composition may …
continued below
Publisher Info:
Lawrence Livermore National Lab., CA (USA)
Place of Publication:
California
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
Shielding calculations were performed for the DIII-D facility at La Jolla to independently assess the biological dose from radiation emitted during operation. These calculations for both the fully shielded and bare configurations are in essential agreement with those done by General Atomics. In addition to the basic test problems run by General Atomics, a bare configuration with additional air outside the facility area was calculated. The addition of air to the bare configuration caused the dose at 100 meters from the DIII-D center-line to increase by fifty-five percent. The inclusion of the various elemental constituents in the soil composition may change the calculated dose, but will not change the shielding factor nor invalidate the overall conclusion of this report. The overall conclusion is that General Atomics and LLNL results are in general agreement. 5 refs., 11 figs., 5 tabs.
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Plechaty, E.F.Verification of shielding calculation on the DIII-D facility at La Jolla, CA: Revision 1,