Feasibility study: comparison of coal- and nuclear-fueled alternatives for process steam and by product electrical power generation for the E. I. Du Pont de Nemours and Company, Incorporated Plant Site, Victoria, Texas

PDF Version Also Available for Download.

Description

The purpose of the study was to evaluate the technical and economic feasibility of a small, (365 MWt) nuclear reactor for supplying process steam and electricity as a replacement for energy sources using increasingly scarce natural gas or oil. The Du Pont Chemical Plant Site at Victoria, Texas, was chosen as representative of industrial installations that require sizeable amounts of process steam and electricity. For comparison purposes conventional coal-fired boilers were also evaluated. It was determined that both nuclear- and coal-based process energy supply systems are technically feasible. For the specific steam/electricity demands at the reference site, the coal-fired plant … continued below

Physical Description

Pages: 156

Creation Information

Creator: Unknown. July 1, 1978.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Creator

  • We've been unable to identify the creator(s) of this report.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

The purpose of the study was to evaluate the technical and economic feasibility of a small, (365 MWt) nuclear reactor for supplying process steam and electricity as a replacement for energy sources using increasingly scarce natural gas or oil. The Du Pont Chemical Plant Site at Victoria, Texas, was chosen as representative of industrial installations that require sizeable amounts of process steam and electricity. For comparison purposes conventional coal-fired boilers were also evaluated. It was determined that both nuclear- and coal-based process energy supply systems are technically feasible. For the specific steam/electricity demands at the reference site, the coal-fired plant proved to be economically more attractive than the nuclear units. For an application requiring a base-loaded supply of saturated steam, utilizing full reactor capacity, the nuclear option appears competitive for coal costing $37/ton in 1978 dollars.

Physical Description

Pages: 156

Notes

Dep. NTIS, MF A01.

Source

  • Other Information: Portions of document are illegible

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • July 1, 1978

Added to The UNT Digital Library

  • July 3, 2018, 8:14 a.m.

Description Last Updated

  • July 20, 2018, 3:16 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 9

Interact With This Report

Here are some suggestions for what to do next.

Top Search Results

We found one place within this report that matches your search. View Now

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Feasibility study: comparison of coal- and nuclear-fueled alternatives for process steam and by product electrical power generation for the E. I. Du Pont de Nemours and Company, Incorporated Plant Site, Victoria, Texas, report, July 1, 1978; United States. (https://digital.library.unt.edu/ark:/67531/metadc1185070/: accessed June 3, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen