PROBLEMS IN ACCOUNTABILITY MEASUREMENTS ASSOCIATED WITH THE INTERIM CHEMICAL PROCESSING PROGRAM
Description:
Available knowledge of precision limits in S.S. accountability measurements and/or calculations by reactor and chemical processing groups is surveyed and summarized. Experienee in comparisons of reactor (production and research) calculations vs. chemical plant accountability measurements is also reported. A general tentative conclusion is that available precisions ( plus or minus 0.54 to plus or minus 0.78%) in chemical plant measurements (bulk and analytical) for fissionable material accountab…
more
Date:
May 28, 1959
Creator:
Arnold, E D & Gresky, A T
Partner: