The demand plot has a 5-set, modified pump decay curve; it shows that 20,000 gpm emergency flow would be required within 80 seconds of complete pump power failure. Bases for the demand curve are constant bulk inlet temperature of 2 C, constant bulk outlet temperature of 95 C, K-3 I&E fuel elements, and initial reactor flow of 188,000 gpm.
Publisher Info:
General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
Place of Publication:
Richland, Washington
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
The demand plot has a 5-set, modified pump decay curve; it shows that 20,000 gpm emergency flow would be required within 80 seconds of complete pump power failure. Bases for the demand curve are constant bulk inlet temperature of 2 C, constant bulk outlet temperature of 95 C, K-3 I&E fuel elements, and initial reactor flow of 188,000 gpm.
Physical Description
8 p.
Notes
OSTI as DE94012695; Paper copy available at OSTI: phone, 865-576-8401, or email, reports@adonis.osti.gov
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Corlett, R. F.Analysis of 100-K emergency water requirements after CGI-844 pump failure,
report,
May 28, 1959;
Richland, Washington.
(https://digital.library.unt.edu/ark:/67531/metadc1311790/:
accessed September 7, 2024),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;