LOFT TECHNICAL REPORT
40 LOFT SMALL BREAK TEST HEROCOUPLE INSTALLATION
I LTR No
LQ-87-80--135
RE-A-80-044
Author r - -
R. M., Fors
PerfoimIng Organizetlon
Applied Mechanics Branch A
LOFT ReYlaw and Approval <V LMD
Mgr.PSB
Mgr.Ae1Eased By LOFT CDOS
Date May 28, 198'Project $yster En - r
ABSTRACT
Tne subject thermocouple design has been analyzed for maximum expected
hydraulic loading and found to be adequate. The natural frequency of the
tnemocouple was found to be beLweeo Gte vortex shedding frequencies for the
gas and liquid phase so that a tendency for resonance will exist. However,
since the thermocouple support will have a restricted displacement, stresses
found are below the endurance limit and, thus, are acceptable in respect to
fatigue life as well as primary stress due to pressure loading,
DISPOSITION OF RECOMENDATIONS
No disposition required.i
FOflM EAG.22a
Rav Di44,
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Fors, R. M. LOFT Small Break Test Themocouple Installation, report, May 28, 1980; United States. (https://digital.library.unt.edu/ark:/67531/metadc841065/m1/3/: accessed April 25, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.