HNF-2705, Rev. 0
CSER 98-003: CRITICALITY SAFETY
EVALUATION REPORT FOR PFP GLOVEBOX
HC-21A WITH BUTTON CAN OPENING
David G. Erickson
Fluor Daniel Northwest, Inc., Richland, WA 99352
U.S. Department of Energy Contract DE-AC06-96RL13200EDT/ECN: 623015
Org Code: 403
B&R Code: EW7003000UC: 510
Charge Code: K6058
Total Pages: 79Key Words: PFP, PLUTONIUM, BUTTONS, HC-21A, THERMAL STABILIZATION
Abstract: This Criticality Safety Evaluation was prepared by Fluor Daniel Northwest
under contract to BWHC. This document establishes the critically safety parameters for
plutonium operations in glovebox HC-21ATRADEMARK DISCLAIMER. Reference herein to any specific commercial product, process, or
service by trade name, trademark, manufacturer, or otherwise, does not necessarily
constitute or imply its endorsement, recommendation, or favoring by the United States
Government or any agency thereof or its contractors or subcontractors.
Printed in the United States of America. To obtain copies of this document. contact:
WHC/BCS Document Control Services, P 0. Box 1970. Mailstop H6-08, Richland WA 99352, Phone
(509) 372-2420: Fax (509) 376-4989.1d'9G8 .:.. ), / .
Dat Release StampRelease Approval
Approved for Public Release
A-6400-073 (10/95) GEF321
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Erickson, D. G. CSER 98-003: Criticality safety evaluation report for PFP glovebox HC-21A with button can opening, report, February 23, 1999; United States. (https://digital.library.unt.edu/ark:/67531/metadc720356/m1/2/: accessed April 25, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.