Consequence analysis of a NaOH solution spray release during addition to waste tank. Revision 2 Page: 33 of 66
This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided to UNT Digital Library by the UNT Libraries Government Documents Department.
Extracted Text
The following text was automatically extracted from the image on this page using optical character recognition software:
HNF-SD-WM-CN-065 Rev 2
c Fluid Dynamic Respirable RR Fitting
c Specific Viscosity Diameter Constant
c Gravity (centi-poise) ( m) (q)
c
1.30900E+00 4.40000E+00 1.49000E+01 2.40000E+00
MESSAGES:
Slit Model
Code search for optimal equivalent diameter.
OUTPUT:
Liquid Velocity = 7.40E+01 ft/s 2.26E+01 m/s
Reynolds Number = 1.04E+03 Laminar Flow
Sauter Mean Diameter = 4.77E+01 m
Optimum Slit Width = 3.06E-03 in 7.77E-05 m
Respirable Fraction = 2.19E-02
Total Leak Rate = 7.06E-01 gpm 4.45E-05 m3/s 5.83E+01 g/s
Respirable Leak Rate = 1.54E-02 gpm 9.74E-07 m3/s 1.28E+00 g/s28 of 60
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Matching Search Results
View three places within this report that match your search.Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Van Vleet, R.J. & Lancing, L.C. Consequence analysis of a NaOH solution spray release during addition to waste tank. Revision 2, report, July 8, 1997; Richland, Washington. (https://digital.library.unt.edu/ark:/67531/metadc677420/m1/33/?q=technical+manual: accessed July 17, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.