A technical basis to relax the dew point specification for the environment in the vapor space in DWPF canisters Page: 4 of 25
This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided to UNT Digital Library by the UNT Libraries Government Documents Department.
Extracted Text
The following text was automatically extracted from the image on this page using optical character recognition software:
ASSET
APPLIED SCIENCE & ENGINEERING TECHNOLOGYWSRC-TR-95-0222
Revision 0Keywords:
DWPF Waste Glass
Canister, Vapor
Space, Dew Point
Specification,
Corrosion
Retention: LifetimeA TECHNICAL BASIS
TO
RELAX THE DEW POINT SPECIFICATION
FOR THE
ENVIRONMENT IN THE VAPOR SPACE IN DWPF CANISTERS (U)McIntyre R. Louthan,
Jr.
Issued: May 1995
D. D
Authorized Derivative Classifier/ Date
S RTC SAVANNAH RIVER TECHNOLOGY CENTER, AIKEN, SC 29808
Westinghouse Savannah River Company
Prepared For The U.S. Department Of Energy Under Contract DE-AC09-89SR 18035
PAAST-I
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Louthan, M. R. Jr. A technical basis to relax the dew point specification for the environment in the vapor space in DWPF canisters, report, May 1, 1995; Aiken, South Carolina. (https://digital.library.unt.edu/ark:/67531/metadc621032/m1/4/: accessed May 14, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.