Report describing small-scale laboratory experiments using a Beckman model 7C thermal conductivity cell conducted in order to provide a better understanding of the response of the hydrogen monitor during Power Burst Facility (PDF) Severe Fuel Damage (SFD) tests (p. 1).
We've identified this
report
as a primary source within our collections. Researchers, educators, and students may find this report useful in their work.
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Report describing small-scale laboratory experiments using a Beckman model 7C thermal conductivity cell conducted in order to provide a better understanding of the response of the hydrogen monitor during Power Burst Facility (PDF) Severe Fuel Damage (SFD) tests (p. 1).
Physical Description
ii, 31 pages : tables, illustrations
Notes
Digitized from microfiche (9).
Part of "Appendix E-Hydrogen Measurements" to report: Power Burst Facility (PBF) Severe Fuel Damage Test 1-4: Test Results Report
Power Burst Facility (PBF) Severe Fuel Damage Test 1-4: Test Results Report, ark:/67531/metadc1202748
Collections
This report is part of the following collection of related materials.
Technical Report Archive and Image Library
The Technical Report Archive & Image Library (TRAIL) identifies, acquires, catalogs, digitizes and provides unrestricted access to U.S. government agency technical reports. The mission of TRAIL is to ensure preservation, discoverability, and persistent open access to government technical publications regardless of form or format.
"A description and evaluation of the major phenomena, based upon the response of on-line instrumentation, analysis of fission product and aerosol data, postirradiation examination of the fuel bundle, and calculations using the SCDAP/RELAP5 computer code, are presented"
Relationship to this item: (Is Referenced By)
Power Burst Facility (PBF) Severe Fuel Damage Test 1-4: Test Results Report, ark:/67531/metadc1202748
Petti, D. A.; Carboneau, M. L; Martinson, Zoel R.; Hobbins, Richard R.; Allison, C. M.; Carlson, E. R. et al.The Beckman 7C Thermal Cell (Hydrogen Monitor) Experiments,
report,
April 1989;
(https://digital.library.unt.edu/ark:/67531/metadc2074275/:
accessed July 18, 2024),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.