Scaleup tests and supporting research for the development of duct injection technology

PDF Version Also Available for Download.

Description

This Topical Report No. 2 is an interim report on the Duct Injection Test Facility being operated for the Department of Energy at Beverly, Ohio. Either dry calcium hydroxide or an aqueous slurry of calcium hydroxide (prepared by slaking quicklime) is injected into a slipstream of flue gas to achieve partial removal of SO{sub 2} from a coal-burning power station. Water injected with the slurry or injected separately from the dry sorbents cools the flue gas and increases the water vapor content of the gas. The addition of water, either in the slurry or in a separate spray, makes the … continued below

Physical Description

Pages: (181 p)

Creation Information

Felix, L. G.; Dismukes, E. B.; Gooch, J. P. (Southern Research Inst., Birmingham, AL (United States)); Klett, M. G. & Demian, A. G. (Gilbert/Commonwealth, Inc., Reading, PA (United States)) April 20, 1992.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publishers

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This Topical Report No. 2 is an interim report on the Duct Injection Test Facility being operated for the Department of Energy at Beverly, Ohio. Either dry calcium hydroxide or an aqueous slurry of calcium hydroxide (prepared by slaking quicklime) is injected into a slipstream of flue gas to achieve partial removal of SO{sub 2} from a coal-burning power station. Water injected with the slurry or injected separately from the dry sorbents cools the flue gas and increases the water vapor content of the gas. The addition of water, either in the slurry or in a separate spray, makes the extent of reaction between the sorbent and the SO{sub 2} more complete; the presumption is that water is effective in the liquid state, when it is able to wet the sorbent particles physically, and not especially effective in the vapor state. An electrostatic precipitator collects the combination of suspended solids (fly ash from the boiler and sorbent from the duct injection process). All of the operations are being carried out on the scale of approximately 50,000 acfm of flue gas.

Physical Description

Pages: (181 p)

Notes

OSTI; NTIS; GPO Dep.

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE92018702
  • Report No.: DOE/PC/88851-T2
  • Report No.: G/C--2782-2
  • Report No.: SRI-ENV--91-471-6715-T2
  • Grant Number: AC22-88PC88851
  • Digital Object Identifier: https://doi.org/10.2172/7205353
  • Office of Scientific & Technical Information Report Number: 7205353
  • Archival Resource Key: ark:/67531/metadc1445988

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • April 20, 1992

Added to The UNT Digital Library

  • Feb. 10, 2019, 8:45 p.m.

Description Last Updated

  • Oct. 4, 2023, 12:55 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Felix, L. G.; Dismukes, E. B.; Gooch, J. P. (Southern Research Inst., Birmingham, AL (United States)); Klett, M. G. & Demian, A. G. (Gilbert/Commonwealth, Inc., Reading, PA (United States)). Scaleup tests and supporting research for the development of duct injection technology, report, April 20, 1992; United States. (https://digital.library.unt.edu/ark:/67531/metadc1445988/: accessed July 16, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen