Acenaphthene solvents for use in Building 313 Frost Test operation

PDF Version Also Available for Download.

Description

Acenaphtheno is a low-melting organic compound, C{sub 10}H{sub 6}(CH{sub 2}){sub 2}, used as a temperature indicating coating for slugs tested in the Frost Test induction coil. In preparation for this test, slugs are coated by spraying a 12 to 24 per cent by weight solution of acenaphthene in a high vapor pressure solvent on the rotating slug. The solvent evaporate leaving a thin, adherent coating of acenaphthene. This process is completely described in reference 1. To be entirely satisfactory for this use, a solvent must satisfy four requirements. High vapor pressure -- rapid evaporation. Non-flammability. Low toxicity. Carbon tetrachloride, the … continued below

Physical Description

5 p.

Creation Information

Kratzer, W. K. June 26, 1951.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Acenaphtheno is a low-melting organic compound, C{sub 10}H{sub 6}(CH{sub 2}){sub 2}, used as a temperature indicating coating for slugs tested in the Frost Test induction coil. In preparation for this test, slugs are coated by spraying a 12 to 24 per cent by weight solution of acenaphthene in a high vapor pressure solvent on the rotating slug. The solvent evaporate leaving a thin, adherent coating of acenaphthene. This process is completely described in reference 1. To be entirely satisfactory for this use, a solvent must satisfy four requirements. High vapor pressure -- rapid evaporation. Non-flammability. Low toxicity. Carbon tetrachloride, the solvent used at percent, is operationally satisfactory but undersirable because of its toxicity. The purpose of this test is to investigate the suitability of various solvents as substituted for carbon tetrachloride.

Physical Description

5 p.

Notes

OSTI; NTIS; GPO Dep.

Source

  • Other Information: PBD: 26 Jun 1951

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • June 26, 1951

Added to The UNT Digital Library

  • Nov. 3, 2018, 11:47 a.m.

Description Last Updated

  • March 25, 2020, 1:28 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 9

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Kratzer, W. K. Acenaphthene solvents for use in Building 313 Frost Test operation, report, June 26, 1951; Richland, Washington. (https://digital.library.unt.edu/ark:/67531/metadc1317227/: accessed July 16, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen