Calculations indicate that the proposed shielding arrangement will give a dose rate at the surface of the water tank of about 100 mrem per hr., practically all gammas. This is adequate for transportation and handling, but if the radiation actually proves to be this high, a storage location isolated from normal working areas must be provided. The isolation area need not be large, however, since the calculated dose rate at 10 feet from the shielded sources is only 3.5 mrem pr hr. For the short time required to transfer the source from the water tank into the reactor the Pb …
continued below
We've identified this
report
as a primary source within our collections. Researchers, educators, and students may find this report useful in their work.
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Added Title:
Oak Ridge National Laboratory Report CF-57-1-107
Description
Calculations indicate that the proposed shielding arrangement will give a dose rate at the surface of the water tank of about 100 mrem per hr., practically all gammas. This is adequate for transportation and handling, but if the radiation actually proves to be this high, a storage location isolated from normal working areas must be provided. The isolation area need not be large, however, since the calculated dose rate at 10 feet from the shielded sources is only 3.5 mrem pr hr. For the short time required to transfer the source from the water tank into the reactor the Pb carrier alone will provide sufficient shielding. At one meter from the source shielded by the Pb carrier, the dose rate is estimated to be 170 mrem per hr., with neutrons contributing he major part. With reasonable care, the operations should be carried out without excessive exposures. The results of the calculations are summarized.
This report is part of the following collections of related materials.
TRAIL Microcard Collection
Imaged from microcard, these technical reports describe research performed for U.S. government agencies from the 1930s to the 1960s. The reports were provided by the Technical Report Archive and Image Library (TRAIL).
The Technical Report Archive & Image Library (TRAIL) identifies, acquires, catalogs, digitizes and provides unrestricted access to U.S. government agency technical reports. The mission of TRAIL is to ensure preservation, discoverability, and persistent open access to government technical publications regardless of form or format.