Simultaneous analysis of uranium and nitrate

PDF Version Also Available for Download.

Description

A direct spectrophotometric method has been developed for the determination of 20 to 200 g/l of uranium in the presence of 3 to 5 M nitric acid. A dual-wavelength analysis is used to eliminate the enhancing effect of nitrate ion on the uranium visible spectra. The precision and accuracy of the simultaneous analysis of uranium and nitrate were compared using combinations of the four uranium wavelength maxima, occurring at 426, 416, 403 and 359 nm. Calculations based on 426 and 416 nm data yielded the most accurate results. The calculated relative standard deviation of uranium and nitrate concentrations was 5.4 … continued below

Physical Description

39 pages

Creation Information

Bostick, D.T. April 1, 1978.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 14 times. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

A direct spectrophotometric method has been developed for the determination of 20 to 200 g/l of uranium in the presence of 3 to 5 M nitric acid. A dual-wavelength analysis is used to eliminate the enhancing effect of nitrate ion on the uranium visible spectra. The precision and accuracy of the simultaneous analysis of uranium and nitrate were compared using combinations of the four uranium wavelength maxima, occurring at 426, 416, 403 and 359 nm. Calculations based on 426 and 416 nm data yielded the most accurate results. The calculated relative standard deviation of uranium and nitrate concentrations was 5.4 percent and 15.5 percent, respectively. The photometric procedure is slightly affected by temperature; an increase of one degree centigrade results in a 0.2 g/l overestimation of uranium concentration. Because the method is non-destructive, it is directly applicable to the continuous in-line analysis of dissolved uranium in aqueous fuel reprocessing streams.

Physical Description

39 pages

Notes

AT

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • April 1, 1978

Added to The UNT Digital Library

  • Jan. 22, 2018, 7:23 a.m.

Description Last Updated

  • Feb. 23, 2021, 9:23 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 1
Total Uses: 14

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Bostick, D.T. Simultaneous analysis of uranium and nitrate, report, April 1, 1978; Tennessee. (https://digital.library.unt.edu/ark:/67531/metadc1061974/: accessed July 16, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen