Picotron 100 streak tubes as a 150-channel photometer

PDF Version Also Available for Download.

Description

The characterization of a streak camera based upon Picotron 100 tube types is given. Both a large (30 cm 1 x 10 cm dia.) and a small (18 cm 1 x 5 cm dia.) version of this design has been tested. Over 150 channels of information are simultaneously time resolved with system S.N.R. of 3 at 100 picosecond time resolution without post intensification. Absolute photometric evaluation is given in the dynamic mode, i.e. while operating in the picosecond time domain. Such quantitative data has been lacking in the past, particularly for multiple channel applications.

Physical Description

3 pages

Creation Information

Majumdar, S.; Weiss, P.B. & Black, J.P. January 1, 1982.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 47 times. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Publishers

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

The characterization of a streak camera based upon Picotron 100 tube types is given. Both a large (30 cm 1 x 10 cm dia.) and a small (18 cm 1 x 5 cm dia.) version of this design has been tested. Over 150 channels of information are simultaneously time resolved with system S.N.R. of 3 at 100 picosecond time resolution without post intensification. Absolute photometric evaluation is given in the dynamic mode, i.e. while operating in the picosecond time domain. Such quantitative data has been lacking in the past, particularly for multiple channel applications.

Physical Description

3 pages

Notes

NTIS, PC A02/MF A01.

Source

  • 26. technical symposium and exhibition of the International Society for Optical Engineering, San Diego, CA, USA, 21 Aug 1982

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Other: DE82021898
  • Report No.: LA-UR-82-2476
  • Report No.: CONF-820822-11
  • Grant Number: W-7405-ENG-36
  • Office of Scientific & Technical Information Report Number: 5074948
  • Archival Resource Key: ark:/67531/metadc1055593

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • January 1, 1982

Added to The UNT Digital Library

  • Jan. 22, 2018, 7:23 a.m.

Description Last Updated

  • April 18, 2019, 11:13 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 47

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Majumdar, S.; Weiss, P.B. & Black, J.P. Picotron 100 streak tubes as a 150-channel photometer, article, January 1, 1982; New Mexico. (https://digital.library.unt.edu/ark:/67531/metadc1055593/: accessed July 17, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen