Picotron 100 streak tubes as a 150-channel photometer
PDF Version Also Available for Download.
Description
The characterization of a streak camera based upon Picotron 100 tube types is given. Both a large (30 cm 1 x 10 cm dia.) and a small (18 cm 1 x 5 cm dia.) version of this design has been tested. Over 150 channels of information are simultaneously time resolved with system S.N.R. of 3 at 100 picosecond time resolution without post intensification. Absolute photometric evaluation is given in the dynamic mode, i.e. while operating in the picosecond time domain. Such quantitative data has been lacking in the past, particularly for multiple channel applications.
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this article.
Follow the links below to find similar items on the Digital Library.
Description
The characterization of a streak camera based upon Picotron 100 tube types is given. Both a large (30 cm 1 x 10 cm dia.) and a small (18 cm 1 x 5 cm dia.) version of this design has been tested. Over 150 channels of information are simultaneously time resolved with system S.N.R. of 3 at 100 picosecond time resolution without post intensification. Absolute photometric evaluation is given in the dynamic mode, i.e. while operating in the picosecond time domain. Such quantitative data has been lacking in the past, particularly for multiple channel applications.
This article is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Majumdar, S.; Weiss, P.B. & Black, J.P.Picotron 100 streak tubes as a 150-channel photometer,
article,
January 1, 1982;
New Mexico.
(https://digital.library.unt.edu/ark:/67531/metadc1055593/:
accessed July 17, 2024),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.