was dented and cracked. It is not possible to
say if thi happened during the test setup or upon
removal of the equipment from the test cell. The
leak in the exhaust line was repaired and the system
was prepared for a liquid hydrogen leak check. The
dewar was tilled wIth MI2 and stabilized at the
normal level for two hours. The system was con-
tinuously checked during thIs two hour period and
no leaks were detected.
2. The East No. 2 system was pressurized with helium
gas to7 psg th no detectabela a presu
decay of approximately 0.1 psi per hour was noted.
The dewar was then filled with LI2 and stabilized
for two hours. No leaks were detected, N.S.A.
portable detectors were utilized for leak checking.
3. The General MonItor gas analyzing system is being
examined and tested for possible inadequacIes and/c:
radiation damage.
3.1.4 Sp~cmjenRemovalndnalysis
All three systems were demated and the specimens and
dosimetry were removed. The dosimetry has been stripped down
and is being processed.
All ape imena h ve been moved c and are now stored in
the Irradiated Materials Liboratory. The specimens will be
measured for final gage length and cross section. Selected
specimens will then bese tiod for metallogr phi c examinat
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Irradiation test, preliminary report, report, May 14, 1965; United States. (https://digital.library.unt.edu/ark:/67531/metadc1025513/m1/93/: accessed May 28, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.