Search Results

Advanced search parameters have been applied.
open access

Cold Vacuum Drying facility HVAC system design description

Description: This System Design Description (SDD) addresses the HVAC system for the CVDF. The CVDF HVAC system consists of five subsystems: (1) Administration building HVAC system; (2) Process bay recirculation HVAC system; (3) Process bay local exhaust HVAC and process vent system; (4) Process general supply/exhaust HVAC system; and (5) Reference air system. The HVAC and reference air systems interface with the following systems: the fire protection control system, Monitoring and Control System (MCS), elec… more
Date: September 22, 2000
Creator: Singh, G.
Partner: UNT Libraries Government Documents Department
open access

Environmental Management Performance Report September 2000

Description: The purpose of this report is to provide the Department of Energy Richland Operations Office (DOE-RL) a monthly summary of the Project Hanford Management Contractor's (PHMC) Environmental Management (EM) performance by Fluor Hanford (FH) and its subcontractors. In addition to project-specific information, it includes some PHMC-level data not detailed elsewhere in the report. Section A, Executive Summary, provides an executive level summary of the cost, schedule, and technical performance descri… more
Date: September 1, 2000
Creator: Eder, D. M.
Partner: UNT Libraries Government Documents Department
open access

Transuranic (TRU) Waste Phase I Retrieval Plan

Description: From 1970 to 1987, TRU and suspect TRU wastes at Hanford were placed in the SWBG. At the time of placement in the SWBG these wastes were not regulated under existing Resource Conservation and Recovery Act (RCRA) regulations, since they were generated and disposed of prior to the effective date of RCRA at the Hanford Site (1987). From the standpoint of DOE Order 5820.2A1, the TRU wastes are considered retrievably stored, and current plans are to retrieve these wastes for shipment to WIPP for dis… more
Date: September 28, 2000
Creator: McDonald, Kent M.
Partner: UNT Libraries Government Documents Department
open access

Fire hazard analysis for the fuel supply shutdown storage buildings

Description: The purpose of a fire hazards analysis (FHA) is to comprehensively assess the risk from fire and other perils within individual fire areas in a DOE facility in relation to proposed fire protection so as to ascertain whether the objectives of DOE 5480.7A, Fire Protection, are met. This Fire Hazards Analysis was prepared as required by HNF-PRO-350, Fire Hazards Analysis Requirements, (Reference 7) for a portion of the 300 Area N Reactor Fuel Fabrication and Storage Facility.
Date: September 27, 2000
Creator: REMAIZE, J.A.
Partner: UNT Libraries Government Documents Department
Back to Top of Screen