Corrosion of the Volatility Pilot Plant Inor-8 Hydrofluorinator and Nickel 201 Fluorinator During Forty Fuel-Processing Runs With Zirconium-Uranium Alloy

Description: This report addresses the corrosion of the volatility pilot plant INOR-8 hydrofluorinator and nickel 201 fluorinator during forty fuel-processing runs with zirconium uranium alloy.
Date: March 1, 1965
Creator: Youngblood, E. L.; Milford, R. P.; Nicol, R. G. & Ruch, J. B.
Partner: UNT Libraries Government Documents Department
open access

Volatility: Fluorinator Design FV-100, Zr-U Fuel Element Processing Phase

Description: Volatility Pilot Plant Mark III Fluorinator is a doublechamber type vessel, each chamber 2 1/2 ft by 16 in. outside diameter separated by a 5-in. pipe 15 in. long. ASME flanged and dished heads are used for the chamber tops and conical sections with a 60 deg apex angle for the chamber bottoms. A new furnace designed to maintain the complete lower chamber (molten salt+ freeboard) above melt temperature is to eliminate past experiences of salt solidification on the wall, heads, and in or on the i… more
Date: May 28, 1959
Creator: Ruch, J. B.
Partner: UNT Libraries Government Documents Department
open access

Corrosion of the Volatility Pilot Plant INOR-8 Hydrofluorinator and Nickel 201 Fluorinator During Forty Fuel-Pprocessing Runs with Zirconium-Uranium Alloy

Description: Report documenting the corrosion of fluorinators of the Oak Ridge National Laboratory's volatility pilot plant. Includes descriptions of the fluorinators, their operating environments, and the results of their corrosion.
Date: March 1965
Creator: Youngblood, E. L.; Milford, R. P.; Nicol, R. G. & Ruch, J. B.
Partner: UNT Libraries Government Documents Department
open access

Volatility: Fluorinator Design FV-100, Zr-U Fuel Element Processing Phase

Description: Volstility Pilot Plant Mark III Fluorinator will be a double-chamber type vessel, each chamber 2-1/2ft. by 16in. o.d. separated by a 5 in. pipe 15 in. long. ASME flanged and dished heads will be used for the chamber tops and conical sections with a 60º apex angle for the chamber bottoms. A new furnace designed to maintain the complete lower chamber (molten salt + freeboard) above melt temperature will eliminate past experiences of salt solidification on the wall, heads, and in or on the interna… more