Search Results

Advanced search parameters have been applied.
open access

Geothermal Loop Experimental Facility. Quarterly report, January--March 1978

Description: The Geothermal Loop Experimental Facility (GLEF) utilizes a four stage flash/binary process for the extraction of energy from a high temperature, high salinity, liquid-dominated resource. Since plant start-up in May 1976, a substantial amount of information has been obtained on the operation of the plant, components, brine and steam composition, production and injection wells, and the potential of the Niland Reservoir. The general operation and activities of the GLEF during the period January 1… more
Date: April 1, 1978
Creator: Bischoff, W. S.; Bishop, H. K.; Cooney, C. S.; Hanenburg, W. H.; Hoaglin, G. J.; Jacobson, W. O. et al.
Partner: UNT Libraries Government Documents Department
open access

Pump, sodium, inducer, intermediate size (ISIP) (impeller/inducer/diffuser retrofit)

Description: This specification defines the requirements for the Intermediate-Size Inducer Pump (ISIP), which is to be made by replacing the impeller of the FFTF Prototype Pump with a new inducer, impeller, diffuser, seal, and necessary adapter hardware. Subsequent testing requirements of the complete pump assembly are included.
Date: April 21, 1978
Creator: Paradise, D.R.
Partner: UNT Libraries Government Documents Department
open access

Hydrodynamic design report intermediate size inducer pump for sodium operation

Description: An inducer pump has been designed to fit within the existing housing of the FFTF Facility. The design has been shown to meet the specified requirements in every area where an analytical prediction of the performance can be made. The head-rise and efficiency of the pump have design margins so that the calculated values actually exceed requirements over the full range of operation. The suction performance of the design provides a very large margin at the operating NPSH value which is the major ad… more
Date: April 26, 1978
Creator: King, J.A.; O'Hern, F.C. & Jackson, E.D.
Partner: UNT Libraries Government Documents Department
open access

Recirculating flow analyses of Intermediate Size Inducer Pump (ISIP)

Description: This report documents the recirculation flow analyses for the Intermediate-Size Inducer Pump (ISIP), from which the primary flowrates through the pump were obtained. The front and rear impeller labyrinth seals, which incorporate stepped pockets with slanted and rounded ribs were checked. These seal design features should minimize the impeller labyrinth seal leakages and also provide excellent shutoff head characteristics.
Date: April 20, 1978
Creator: Hoshide, R.K.
Partner: UNT Libraries Government Documents Department
open access

Survey of industrial coal conversion equipment capabilities: rotating components

Description: At the request of the Major Facilities Project Management Division of the Energy Research and Development Administration, Fossil Energy Division, a study was undertaken to determine the capabilities of U.S. industry to supply the rotating equipment needed for future coal conversion facilities. Furthermore, problem areas were to be identified and research and development needs determined for producing advanced designs of the required equipment: Pumps, compressors, hydraulic turbines, and gas exp… more
Date: April 1, 1978
Creator: Williams, W. R.; Horton, J. R.; Boudreau, W. F. & Siman-Tov, M.
Partner: UNT Libraries Government Documents Department