HYBRID SULFUR ELECROLYZER DEVELOPMENT, NHI WORK PACKAGE N-SR07TC0301, FY08 FIRST QUARTER REPORT

Description: Hydrogen has been identified as a leading candidate to replace petroleum as part of the transition to a sustainable energy system, and major efforts are being conducted worldwide to develop the technologies and supporting activities required for this transition. In the United States, the federal research efforts are led by the U.S. Department of Energy (DOE). The U.S. DOE Hydrogen Program is an integrated inter-office program being conducted by the Office of Energy Efficiency and Renewable Ener… more
Date: December 20, 2007
Creator: Summers, W
Partner: UNT Libraries Government Documents Department
open access

Enhancing the use of coals by gas reburning-sorbent injection

Description: The objective of this project is to evaluate and demonstrate a cost effective emission control technology for acid rain precursors, oxides of nitrogen (NO{sub x}) and sulfur (SO{sub x}), on two coal fired utility boilers in Illinois. The specific objectives are to demonstrate reductions of 60 percent in NO{sub x} and 50 percent in SO{sub x} emissions, by a combination of two developed technologies, gas reburning (GR) and sorbent injection (SI). With GR, about 80--85 percent of the coal fuel is … more
Date: October 20, 1990
Partner: UNT Libraries Government Documents Department
open access

Integrated low emissions cleanup system for direct coal fueled turbines (moving bed, fluid bed contactor/ceramic filter)

Description: The United States Department of Energy, Morgantown Energy Research Center (DOE/METC), is sponsoring the development of direct coal-fired turbine power plants as part of their Heat Engines program. A major technical challenge remaining for the development of the direct coal-fired turbine is high-temperature combustion gas cleaning to meet environmental standards for sulfur oxides and particulate emissions, as well as to provide acceptable turbine life. The Westinghouse Electric Corporation, Scie… more
Date: October 20, 1992
Creator: Newby, R. A.; Alvin, M. A.; Bachovchin, D. M.; Yang, W. C.; Smeltzer, E. E. & Lippert, T. E.
Partner: UNT Libraries Government Documents Department
open access

Integrated low emissions cleanup system for direct coal fueled turbines (moving bed, fluid bed contactor/ceramic filter). Twentieth quarterly status report, July--September 1992

Description: The United States Department of Energy, Morgantown Energy Research Center (DOE/METC), is sponsoring the development of direct coal-fired turbine power plants as part of their Heat Engines program. A major technical challenge remaining for the development of the direct coal-fired turbine is high-temperature combustion gas cleaning to meet environmental standards for sulfur oxides and particulate emissions, as well as to provide acceptable turbine life. The Westinghouse Electric Corporation, Scie… more
Date: October 20, 1992
Creator: Newby, R. A.; Alvin, M. A.; Bachovchin, D. M.; Yang, W. C.; Smeltzer, E. E. & Lippert, T. E.
Partner: UNT Libraries Government Documents Department
open access

CLOSE-OUT REPORT FOR HYS ELECTROLYZER COMPONENT DEVELOPMENT WORK AT SAVANNAH RIVER NATIONAL LABORATORY

Description: The chemical stability, sulfur dioxide transport, ionic conductivity, and electrolyzer performance have been measured for several commercially available and experimental proton exchange membranes (PEMs) for use in a sulfur dioxide depolarized electrolyzer (SDE). The SDE's function is to produce hydrogen by using the Hybrid Sulfur (HyS) Process, a sulfur based electrochemical/thermochemical hybrid cycle. Membrane stability was evaluated using a screening process where each candidate PEM was heat… more
Date: January 20, 2010
Creator: Colon-Mercado, H.; Elvington, M. & Hobbs, D.
Partner: UNT Libraries Government Documents Department
open access

Effect of Environmental Factors on Sulfur Gas Emissions from Drywall

Description: Problem drywall installed in U.S. homes is suspected of being a source of odorous and potentially corrosive indoor pollutants. The U.S. Consumer Product Safety Commission's (CPSC) investigation of problem drywall incorporates three parallel tracks: (1) evaluating the relationship between the drywall and reported health symptoms; (2) evaluating the relationship between the drywall and electrical and fire safety issues in affected homes; and (3) tracing the origin and the distribution of the dryw… more
Date: August 20, 2011
Creator: Maddalena, Randy
Partner: UNT Libraries Government Documents Department
open access

HYBRID SULFUR ELECTROLYZER DEVELOPMENT, NHI WORK PACKAGE N-SR07TC0301, FY07 FIRST QUARTER REPORT

Description: The proof of concept of SO2 electrolysis for the hybrid sulfur (HyS) process is the second priority research target of the DOE Nuclear Hydrogen Initiative's thermochemical program for FY07. The proof of concept of the liquid-phase option must be demonstrated at the single cell level for an extended run times (>100 hours). The rate of development of HyS will depend on the identification of a promising membrane or an alternative means for controlling sulfur formation. Once successful long-dura… more
Date: December 20, 2006
Creator: Summers, W
Partner: UNT Libraries Government Documents Department
open access

Final Report, "Laboratory Studies of the Role of Sea Salt Bromine in Determining Tropospheric Ozone"

Description: This document is a final report for the project DE-FG03-98ER62578, "Laboratory Studies of the Role of Sea Salt Bromine in Determining Tropospheric Ozone". It includes a technical summary, collaborations, educational contributions and the peer-reviewed scientific publications that have resulted from this research.
Date: June 20, 2005
Creator: Finlayson-Pitts, B. J.
Partner: UNT Libraries Government Documents Department
open access

Integrated low emissions cleanup system for direct coal fueled turbines (moving bed, fluid bed contactor/ceramic filter)

Description: The United States Department of Energy, Morgantown Energy Research Center (DOE/METC), is sponsoring the development of direct coal-fired turbine power plants as part of their Heat Engines program. A major technical challenge remaining for the development of the direct coal-fired turbine is high-temperature combustion gas cleaning to meet environmental standards for sulfur oxides and particulate emissions, as well as to provide acceptable turbine life. The Westinghouse Electric Corporation, Scie… more
Date: April 20, 1992
Creator: Newby, R. A.; Alvin, M. A.; Bachovchin, D. M.; Yang, W. C.; Smeltzer, E. E. & Lippert, T. E.
Partner: UNT Libraries Government Documents Department
open access

High SO[sub 2] removal efficiency testing

Description: This project involves testing at full-scale utility flue gas desulftirization (FGD) systems to evaluate low capital cost upgrades that may allow these systems to achieve up to 98% SO[sub 2] removal efficiency. The options to be evaluated primarily involve the addition of organic acid buffers to the FGD systems. The base'' project involves testing at one site, the Tampa Electric Company Big Bend Station. Up to five optional sites may be added to the program at the discretion of DOE-PETC. By 30 S… more
Date: October 20, 1992
Creator: Blythe, G.
Partner: UNT Libraries Government Documents Department
open access

High SO{sub 2} removal efficiency testing. Technical progress report

Description: This project involves testing at full-scale utility flue gas desulftirization (FGD) systems to evaluate low capital cost upgrades that may allow these systems to achieve up to 98% SO{sub 2} removal efficiency. The options to be evaluated primarily involve the addition of organic acid buffers to the FGD systems. The ``base`` project involves testing at one site, the Tampa Electric Company Big Bend Station. Up to five optional sites may be added to the program at the discretion of DOE-PETC. By 30… more
Date: October 20, 1992
Creator: Blythe, G.
Partner: UNT Libraries Government Documents Department
open access

Integrated low emissions cleanup system for direct coal fueled turbines (moving bed, fluid bed contactor/ceramic filter). Eighteenth quarterly status report, January--March 1992

Description: The United States Department of Energy, Morgantown Energy Research Center (DOE/METC), is sponsoring the development of direct coal-fired turbine power plants as part of their Heat Engines program. A major technical challenge remaining for the development of the direct coal-fired turbine is high-temperature combustion gas cleaning to meet environmental standards for sulfur oxides and particulate emissions, as well as to provide acceptable turbine life. The Westinghouse Electric Corporation, Scie… more
Date: April 20, 1992
Creator: Newby, R. A.; Alvin, M. A.; Bachovchin, D. M.; Yang, W. C.; Smeltzer, E. E. & Lippert, T. E.
Partner: UNT Libraries Government Documents Department
open access

Global emissions and models of photochemically active compounds

Description: Anthropogenic emissions from industrial activity, fossil fuel combustion, and biomass burning are now known to be large enough (relative to natural sources) to perturb the chemistry of vast regions of the troposphere. A goal of the IGAC Global Emissions Inventory Activity (GEIA) is to provide authoritative and reliable emissions inventories on a 1{degree} {times} 1{degree} grid. When combined with atmospheric photochemical models, these high quality emissions inventories may be used to predict … more
Date: May 20, 1993
Creator: Penner, J. E.; Atherton, C. S. & Graedel, T. E.
Partner: UNT Libraries Government Documents Department
open access

High SO{sub 2} removal efficiency testing: PSI Energy`s Gibson Station High SO{sub 2} Removal Efficiency Test Program

Description: A program was conducted at PSI Energy`s Gibson Generating Station to evaluate options for achieving high sulfur dioxide (SO{sub 2}) removal efficiency with the Unit 5 wet limestone flue gas desulfurization (FGD) system. This program was one of six conducted by the U.S. Department of Energy to evaluate low-capital-cost upgrades to existing FGD systems as a means for utilities to comply with the requirements of the 1990 Clean Air Act Amendments (CAAA). The Gibson FGD system employs four absorber … more
Date: May 20, 1996
Partner: UNT Libraries Government Documents Department
open access

Flue gas dry scrubbing using pulsed electron beams

Description: Electron beam dry scrubbing is a technique for removing in a single step both nitrogen oxides (NO{sub x}) and sulfur dioxide (SO{sub 2}) from the off-gas generated by utilities burning high sulfur coal. The use of pulsed electron beams may provide the most cost-effective solution to the implementation of this technique. This paper presents the results of plasma chemistry calculations to study the effect of dose rate, pulse length and pulse repetition rate on pulsed electron beam processing of N… more
Date: February 20, 1996
Creator: Penetrante, B.M.
Partner: UNT Libraries Government Documents Department
open access

Scaleup tests and supporting research for the development of duct injection technology

Description: This Topical Report No. 2 is an interim report on the Duct Injection Test Facility being operated for the Department of Energy at Beverly, Ohio. Either dry calcium hydroxide or an aqueous slurry of calcium hydroxide (prepared by slaking quicklime) is injected into a slipstream of flue gas to achieve partial removal of SO{sub 2} from a coal-burning power station. Water injected with the slurry or injected separately from the dry sorbents cools the flue gas and increases the water vapor content o… more
Date: April 20, 1992
Creator: Felix, L. G.; Dismukes, E. B.; Gooch, J. P. (Southern Research Inst., Birmingham, AL (United States)); Klett, M. G. & Demian, A. G. (Gilbert/Commonwealth, Inc., Reading, PA (United States))
Partner: UNT Libraries Government Documents Department
open access

Scaleup tests and supporting research for the development of duct injection technology. Topical report No. 2, Task 3.1: Evaluation of system performance, Duct Injection Test Facility, Muskingum River Power Plant, Beverly, Ohio

Description: This Topical Report No. 2 is an interim report on the Duct Injection Test Facility being operated for the Department of Energy at Beverly, Ohio. Either dry calcium hydroxide or an aqueous slurry of calcium hydroxide (prepared by slaking quicklime) is injected into a slipstream of flue gas to achieve partial removal of SO{sub 2} from a coal-burning power station. Water injected with the slurry or injected separately from the dry sorbents cools the flue gas and increases the water vapor content o… more
Date: April 20, 1992
Creator: Felix, L. G.; Dismukes, E. B.; Gooch, J. P.; Klett, M. G. & Demian, A. G.
Partner: UNT Libraries Government Documents Department