The Contamination of Cooling Water by a P-9 Plant

Description: The following sources of contamination in cooling water of the P-9 plant are considered: (1) Fission recoils, (2) Corrosion of metal, (3) Recoil from aluminum, (4) Induced activity in the water. It is found that for a P-9 plant of 3.5 x 10(4) KW contamination of the river at "X" should not exceed the .1 r criterion unless coating failure occurs. Tables of the amount of coating failure permissible are given as a function of holdup time.
Date: June 1, 1943
Creator: Friedman, Francis L. (Francis Lee), 1918-
Partner: UNT Libraries Government Documents Department
open access

Fuel Element Transient Temperature Studies

Description: A method is presented for the analysis of transient temperatures in a homogeneous circular cylindrical fuel element in a coolant channel with no axial conduction and no heat loss to the channel wall. In addition, some results were obtained for mean fuel element temperatures in power transients for a simpler model, but accounting for details of the axial coolant temperature distribution in the unsteady state. (auth).
Date: November 1, 1961
Creator: Thompson, J. J.
Partner: UNT Libraries Government Documents Department