Optimization of disk generator performance for base-load power plant systems applications
Description:
Disk generators for use in base-load MHD power plants are examined for both open-cycle and closed-cycle operating modes. The OCD cases are compared with PSPEC results for a linear channel; enthalpy extractions up to 23% with 71% isentropic efficiency are achievable with generator inlet conditions similar to those used in PSPEC, thus confirming that the disk configuration is a viable alternative for base-load power generation. The evaluation of closed-cycle disks includes use of a simplified cyc…
more
Date:
January 1, 1980
Creator:
Teare, J. D.; Loubsky, W. J.; Lytle, J. K. & Louis, J. F.
Partner: