LOFT emergency core coolant thermal analysis Class I review
Description:
The LOFT Emergency Core Coolant Piping Thermal Analysis was checked to insure that the calculations made would conservatively satisfy the requirements in the LOFT technical specifications. Some of the boundary conditions used have not been shown to be conservative and require review and possible re-analysis. One of the thermal models used could not be clearly related to a specific part of the piping geometry and requires further explanation. The remainder of the models, the use of the SIMIR cod…