Search Results

open access

Infrared Absorption Measurements Indicating Intermolecular Association of Water and Hexone

Description: This report analyzes infrared absorption measurements that were made in the regions of carbonyl band and hydroxyl band absorptions on solutions of water in hexone and water in acetone, confirming intermolecular association of water and hexone.
Date: March 8, 1950
Creator: Moore, R. H.
Partner: UNT Libraries Government Documents Department
open access

Preliminary Evaluation of Chlorine for Use as a Gas Cooled Reactor Safeguard*

Description: A coolant line rupture during operation of a high temperature gas cooled graphite moderated reactor would present a serious hazard. The reactor would immediately depressurize and a great deal of air would be introduced into the coolant stream. As the air passed over the graphite moderator a runaway oxidation reaction would probably ensue unless an adequate safety system were available. This investigation was designed to evaluate chlorine as a reactor safeguard to be used to control a runaway re… more
Date: March 8, 1960
Creator: Dahl, R. E.
Partner: UNT Libraries Government Documents Department
open access

Critical Pressure Ratio for a Nozzle with Two-Phase Fog Flow

Description: In many cases of analysis of two-phase flow in systems, considerable computation or program time could be saved if the critical pressures ratio were known. If a reservoir or plenum pressure is fixed, the usual computational procedure involves the assumption of several critical pressures and the generation of several momentum terms to find the applicable critical pressure ratio and thereby the critical flow. The formulation of an equation of state make it possible to compute critical pressure ra… more
Date: March 8, 1960
Creator: Love, W. J.
Partner: UNT Libraries Government Documents Department
open access

Glove Box Integrity Study

Description: The amount of dry air or inert gas supplied to a "one pass" glove box ventilation system is proportional to the glove box inleakage. Most glove boxes in the 234r5 Building are equipped with sundry attachments, each contributing to the inleakage. No individual leak rate date is available for these auxiliary components in the "as installed" condition. Nor is the effect of time upon the leak rates known. Knowledge of these values, or at least an indication of the order of magnitude of the leakage … more
Date: March 8, 1960
Creator: Ciccarelli, R. A.
Partner: UNT Libraries Government Documents Department
open access

100-N Decontamination Facility Design Guide.

Description: Space has been reserved near the southeast corner of the 100-N Area for the 122-N Decontamination Facility. Previous correspondence between Burns and Roe, Inc and General Electric bae discussed various facilities which might be needed in the building. The concepts of the decontamination processes are under active development by research groups at Hanford. At present, there are several workable processes known; each one has one or more fairly serious drawbacks.
Date: March 8, 1960
Creator: Bainard, W. D.
Partner: UNT Libraries Government Documents Department