Corrosion monitoring of storage bins for radioactive calcines Page: 15 of 21
17 p.View a full description of this article.
Extracted Text
The following text was automatically extracted from the image on this page using optical character recognition software:
TABLE 3
CORROSION EXPERIENCE
IN ZIRCONIUM CALCINE PRODUCT.'ype
illovType
CouponNISI 304L Plates
Cylinders
lISI 304 Plates
Cylinders
AISI 405 Plates
Cylinders
AISI 1025 Plates
(0.25% C)
CylindersProjected Corrosion
Average Corrosion Rate After 500 Years Service
(Mil Per Year) (Mil)0.010
0.007
0.008
0.012
0.032
0.052
0.079
0.0564.9
3.7
4.0
5.9
16.0
27.0
40.0
28.0Corrosion Allowance
at
95% Confidence Level
(Mil)5
740
50~- - -
;i
a
Upcoming Pages
Here’s what’s next.
Search Inside
This article can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Article.
Hoffman, T.L. Corrosion monitoring of storage bins for radioactive calcines, article, January 1, 1975; United States. (https://digital.library.unt.edu/ark:/67531/metadc871396/m1/15/: accessed July 17, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.