241-AY-102 Leak Detection Pit Drain Line
Inspection Report
K.D. Boomer, J.K. Engeman
J.R. Gunter, C.C. Joslyn,
B.J. Vazquez, T.J. Venetz
Washington River Protection Solutions, LLC.
Richland, WA 99352
U.S. Department of Energy Contract DE-AC27-08RV14800EDT/ECN: DRF
Cost Center: 2KE00
B&R Code: N/AUC: N/A
Charge Code: 201334
Total Pages: 66 JDA 1/20/14Key Words: Robot, Inspection, Tank 241-AY-102, IHI Southwest Technologies Inc., Leak Detection Pit
Abstract: This document provides a description of the design components, operational approach, and
results from the Tank AY 102 leak detection pit drain piping visual inspection. To perform this inspection,
a custom robotic crawler with a deployment device was designed, built, and operated by IHI for WRPS to
inspect the 6 in. leak detection pit drain line.TRADEMARK DISCLAIMER. Reference herein to any specific commercial product, process, or service by trade name,
trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or
favoring by the United States Government or any agency thereof or its contractors or subcontractors.APPROVED
By Janis D. Aardal at 12:51 pm, Jan 20, 2014Release Approval
Date
DATE:
FORD
Jan 20, 2014 RELEASE
Release StampApproved For Public Release
A-6002-767 (REV 3)
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Boomer, Kayle D.; Engeman, Jason K.; Gunter, Jason R.; Joslyn, Cameron C.; Vazquez, Brandon J.; Venetz, Theodore J. et al. 241-AY-102 Leak Detection Pit Drain Line Inspection Report, report, January 20, 2014; Richland, Washington. (https://digital.library.unt.edu/ark:/67531/metadc865947/m1/7/: accessed July 17, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.