The following text was automatically extracted from the image on this page using optical character recognition software:
Table 12. Response rate investigations - Comparison of
Measured and Calculated Time Constants
Test 1
Test 2
Test 3/1
Test 3/2
Test 3/3
Mass of bed
Id
2054
1328
889
1109
1842
Specific heat of bed
Btu/Ib °R
0.305
0.301
0.304
0.301
0.309
Mass of uncooled tubes
lb
687
301
189
155
668
Specific heat of tube material
Btu/lb°R
0.2
0.2
0.2
0.2
0.2
Five gas flew rate
lb/sec
2.76
3.11
2.88
1.95 :
2.78
Specific heat of flue gas
Btu/lb°R
0.286
0.281
0.286
0.281
0.286
Area of cooling surface -
ft2
34.67
57.6
38.52
41.09
38.52
Average overall heat
transfer coefficient
Btu/sec ft2 °R
0.015
0.014
0.014
0.013
0.015
Calculated time constant (T )
c
-sec
582
274
223
331
510
Measured time constant (T } -
m
sec
700
380
280
450
700
T /T
m—c
1.2
1.39
1.26
1.36
1.37
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Roberts, A. G.; Pillai, K. K.; Raven, P. & Wood, P. Pressurized fluidized-bed combustion part-load behavior. Volume I. Summary report, report, September 1, 1981; United States. (https://digital.library.unt.edu/ark:/67531/metadc1088075/m1/109/: accessed July 18, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.