In an effort to determine the cesium decontamination factors (DF`s) of the Defense Waste Processing Facility (DWPF) melter off-gas system at the Savannah River Site, the system was verified during an off-gas performance test. The off-gas performance test occurred during the DWPF waste Qualification Campaigns, WP-16 and WP-17. The verification of the off-gas system, which eliminated the need for a startup test involving a radioactive cesium addition, was based on the analysis of nonradioactive cesium across the first and second stage High Efficiency Particulate Air (HEPA) filters. The amount of cesium on the first and second stage HEPA filters was …
continued below
Publisher Info:
Westinghouse Savannah River Co., Aiken, SC (United States)
Place of Publication:
Aiken, South Carolina
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this article.
Follow the links below to find similar items on the Digital Library.
Description
In an effort to determine the cesium decontamination factors (DF`s) of the Defense Waste Processing Facility (DWPF) melter off-gas system at the Savannah River Site, the system was verified during an off-gas performance test. The off-gas performance test occurred during the DWPF waste Qualification Campaigns, WP-16 and WP-17. The verification of the off-gas system, which eliminated the need for a startup test involving a radioactive cesium addition, was based on the analysis of nonradioactive cesium across the first and second stage High Efficiency Particulate Air (HEPA) filters. The amount of cesium on the first and second stage HEPA filters was determined by leaching samples from each HEPA filter with nitric acid and analyzing the leachate using Inductively Coupled Plasma - Mass Spectrometry (ICP-MS). The ICP-MS method has been demonstrated to be sufficiently sensitive to measure small quantities of cesium on filters. Based on the cesium results of the HEPA filter, cesium DF`s were calculated. The DF`s indicated that the DWPF HEPA filters performed better than the design basis. In addition to the HEPA filters, a determination of the cesium concentration in the melter feed, the canister glass and the off-gas condensate was made. These analyses provided information on cesium flow through the DWPF. This paper will focus on the methods used in the determination of nonradioactive cesium and the calculation of the DF`s for the DWPF melter off-gas system.
This article is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Andrews, M.K.; Elder, H.H. & Boyce, W.T.Cesium determination for the DWPF off-gas system performance test,