Results of Tritium Tracking and Groundwater Monitoring at the Hanford Site 200 Area State-Approved Land Disposal Site--Fiscal Year 2000

One of 173 items in the series: Fiscal Year 2000 available on this site.

PDF Version Also Available for Download.

Description

The Hanford Site 200 Area Effluent Treatment Facility (ETF) processes contaminated liquids derived from Hanford Site facilities. Groundwater monitoring for tritium and other constituents is required by the state-issued permit at 22 wells surrounding the facility. Water level measurements in nearby wells indicate that a small hydraulic mound exists around the SALDS facility as a result of discharges. Evaluation of this condition indicates that the network is currently adequate for tracking potential effects of the SALDS on the groundwater. During FY 2000, average tritium activities in most wells declined from average activities in 1999. The exception was deep well 699-48-77C, … continued below

Physical Description

PDFN

Creation Information

Barnett, D. Brent September 26, 2000.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 12 times. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Titles

  • Main Title: Results of Tritium Tracking and Groundwater Monitoring at the Hanford Site 200 Area State-Approved Land Disposal Site--Fiscal Year 2000
  • Series Title: Fiscal Year 2000

Description

The Hanford Site 200 Area Effluent Treatment Facility (ETF) processes contaminated liquids derived from Hanford Site facilities. Groundwater monitoring for tritium and other constituents is required by the state-issued permit at 22 wells surrounding the facility. Water level measurements in nearby wells indicate that a small hydraulic mound exists around the SALDS facility as a result of discharges. Evaluation of this condition indicates that the network is currently adequate for tracking potential effects of the SALDS on the groundwater. During FY 2000, average tritium activities in most wells declined from average activities in 1999. The exception was deep well 699-48-77C, where tritium results were at an all-time high (710,000 pCi/L) as a result of the delayed penetration of effluent deeper into the aquifer. Of the 12 constituents with permit enforcement limits, which are monitored in SALDS proximal wells, all were within groundwater limitations during FY 2000. Analyses for conductivity, total dissolved solids, sulfate, chloride, sulfate, dissolved calcium, and dissolved sodium indicate that well 699-48-77A and, to a lesser extent, well 699-48-77D show the effects of dilute effluent entering groundwater, resulting in a depression of concentrations of these constituents below natural background levels. Recommendations for future monitoring include temporarily increasing the frequency of tritium sampling at wells 299-W7-3, 299-W7-5, and 299-W7-7 to quarterly. This measure may assist in a more accurate determination of the southern bounds of the SALDS-generated tritium plume, provide estimates of travel time for model comparisons, and help preserve the distinction between this plume and the older 200 West tritium plume further east.

Physical Description

PDFN

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • September 26, 2000

Added to The UNT Digital Library

  • Jan. 12, 2019, 4:41 p.m.

Description Last Updated

  • Feb. 6, 2019, 1:11 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 12

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Barnett, D. Brent. Results of Tritium Tracking and Groundwater Monitoring at the Hanford Site 200 Area State-Approved Land Disposal Site--Fiscal Year 2000, report, September 26, 2000; Richland, Washington. (https://digital.library.unt.edu/ark:/67531/metadc1396751/: accessed May 26, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen