Search Results

open access

Design Modifications to the SRE during FY 1960

Description: Abstract: The means to prevent the recurrence of tetralin leakage into the SRE sodium systems are discussed. Included is a description of the redesign of system components to utilize alternate coolants such as nitrogen, air, and NaK.
Date: February 15, 1961
Creator: Deegan, G. E.; Dermer, M. D.; Flanagan, J. S.; Gower, G. C.; Hall, R. J.; Hinze, R. B. et al.
Partner: UNT Libraries Government Documents Department
open access

Evaluation of Kanigen, Electroless Nickel Plating for Steam Side of a Sodium Component Steam Generator

Description: Introduction: This is a final report on the evaluation of Kanigen electroless nickel plating for surfaces in contact with water and steam i a sodium heated AISI Type 316 stainless steel steam generator. The purpose of the coasting was to afford protection from stress corrosion cracking originating on the water-steam side of the unit. It has been concluded that the kanigen coating does not afford adequate protection for the services condition intended. This work was performed as part of the research and development program for the United States Atomic Energy Commission sodium Components Design Project.
Date: February 15, 1961
Creator: Alco Products (Firm).
Partner: UNT Libraries Government Documents Department