Activity Build-Up Control by High pH Coolant. A Literature Survey
Description:
A survey was made of unclassified literature dealing with the control of activity build-up in pressurized water reactors by high-pH coolants. Survey results indicate that a high-pH coolant is desirable for control of induced radioactivity build-up in pressurized water reactors containing significant amounts of stainless steel and that no significant hazards are introduced by adoption of a high-pH coolant. Lithium hydroxide was found to be the most acceptable agent for coolant pH control. Strong…
more
Date:
January 23, 1961
Creator:
Bergen, C. R.