Search Results

open access

Low Frequency Amplifier IH-130-1

Description: A tranistorized d.c. coupled amplifier having very good gain stability, as well as very low drift of the output d.c. level, has been designed. Low frequency input signals with an amplitude of .04 to 2 volts peak-to-peak, approximately, coming from a low impedance source (voice soil of a speaker system) are amplified to an approximate peak-to-peak amplitude of 4 volts. The output is intended to drive a load of the order of 100 kohm.
Date: October 23, 1961
Creator: Llacer, Jorge
Partner: UNT Libraries Government Documents Department
open access

Biology Division Semiannual Progress Report for Period Ending August 15, 1961

Description: Members of the Biology Division presented 168 lectures during the period February to August 1961, compared with 116 for each of the two preceding reporting periods. Of these, 96 were before professional societies at home and abroad, and 28 were presented as part of the Traveling Lecture Program.
Date: October 23, 1961
Partner: UNT Libraries Government Documents Department
open access

Owner-operator process and functional requirements interim modifications for improved coolant backup 100-B, C, D, DR, F, and H Reactors, Project CGI-905. Revision 1

Description: This document defines the user,s process and functional requirements which shall be used as the basis for the preparation of the design for Project CGI-905, Interim Modifications for improved Coolant Backup 100-B, C, D, DR, F, and H Reactors. The objective in making these modifications is to provide improved reliability and adequacy in the last ditch reactor cooling systems for current and short-range forecast conditions. Performance requirements for the last ditch cooling system are based on the reactor cooling System criteria set forth in Document HW 66929. These performance criteria require that the last ditch cooling system be independent of both the primary and secondary cooling system, including piping to the reactor manifold, and that it must be capable of providing shutdown flow indefinitely, assuming instantaneous loss of power to the primary system and concurrent failure of the secondary system to provide its rated flow. The purpose of this document is to define the process requirements of the modifications and additions to the last ditch cooling systems and to outline the functional descriptions of the proposed equipment.
Date: October 23, 1961
Creator: Schack, M. H. & Tupper, W. J.
Partner: UNT Libraries Government Documents Department
open access

Error analysis of the TAI equation

Description: There is a certain tolerance of error implicit in any calculation based upon measured physical data. Occasionally, the error is explicitly recognized by attaching a plus or minus variation to the calculated quantity. More often, however, the error is simply neglected. The present analysis was performed to quantify the error implicit in a typical TAI (Trip-After-Instability) limit calculation. This error results from the precision of measurement of each of the parameters used in the calculation of the TAI limit. Though not specifically considered, the results of this work could be used to establish the required minimum level of accuracy of the tube outlet temperature monitoring equipment. Further, some of the generalized equations could probably be programmed into the ROL (Reactor Operating Limits) to indicate how far each Panellit gauge could be ``rolled`` without exceeding a fixed minimum TAI limit. Since the examination of these other possibilities is beyond the scope of this report, they are left as suggestions for future work only.
Date: October 23, 1961
Creator: Cremer, B. R.
Partner: UNT Libraries Government Documents Department
captions transcript

[News Clip: GOP women]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about the biennial conference of the Texas Federation of Republic Women.
Date: October 23, 1961
Duration: 1 minute 46 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
captions transcript

[News Clip: 49th]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about the 49th Armored Division being called into active duty.
Date: October 23, 1961
Duration: 3 minutes 24 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
captions transcript

[News Clip: Flower show]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about the 7th annual Fort Worth Flower Show.
Date: October 23, 1961
Duration: 48 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
captions transcript

[News Clip: Plane crash]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about a plane crash that injured four people and a bullsnake.
Date: October 23, 1961
Duration: 1 minute 29 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
captions transcript

[News Clip: Fed courthouse]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about recommendations for the location of the new federal courthouse.
Date: October 23, 1961
Duration: 1 minute 49 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
captions transcript

[News Clip: Press club]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about the Fort Worth Press Club opening day and luncheon.
Date: October 23, 1961
Duration: 1 minute 31 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
open access

Critical mass control specifications: Hoods 7-C and 9-B

Description: This report discusses the critical mass control specifications for Hoods 7-C and 9-B have become obsolete due to needed storage within the confines of Hood 9-C, and equipment modifications. Nuclear safety in Hood 7-C and 9-B depends almost entirely on controlling the mass and geometry of the plutonium compounds not confined by the processing equipment. Generally, the processing vessels and associated piping are designed and arranged in the hood to be critically safe at full operating capacity. This safety is not assured, however, if plutonium masses outside of the equipment exceed certain proportions of geometry and mass. For those cases where always safe geometry confinement cannot be assured, administrative controls are established.
Date: January 23, 1961
Creator: Smith, R. E.
Partner: UNT Libraries Government Documents Department
open access

Analog to digital converter system for temperature monitoring -- B, C, D, DR, F, and H reactors

Description: This document discusses a proposal that certain presently installed reactor process water outlet temperature data logging equipment in subject reactors to be replaced with new functionally simplified equipment of a more adequate design. The primary purpose of the proposed installation is to replace existing equipment which is obsolete and in three reactors is worn out to the point where the equipment is out of service frequently for periods of time up to 8 hours or more. The new equipment will provide reliable process tube temperature information for use in the functions of reactor control and product accountability. Based upon anticipated incremental production gains resulting from use of the new equipment, the amortization period for the project is calculated at 2.7 years.
Date: March 23, 1961
Creator: Ballowe, J. W.
Partner: UNT Libraries Government Documents Department
captions transcript

[News Clip: Lily Pons]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about the Lily Pons exhibition at the Dallas Museum for Contemporary Arts.
Date: April 23, 1961
Duration: 1 minute 24 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
captions transcript

[News Clip: Fire death]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about a fatal fire at 5004 East Side Street in Dallas.
Date: April 23, 1961
Duration: 1 minute 05 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
captions transcript

[News Clip: Miss Wool contest]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about the fourth annual Miss Wool of America Pageant.
Date: April 23, 1961
Duration: 1 minute 18 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
captions transcript

[News Clip: Sewer project]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about the Gibraltar Construction Company seeking to improve the Dallas drainage system.
Date: April 23, 1961
Duration: 3 minutes 06 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
captions transcript

[News Clip: Tennis match]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about the Dallas Invitational Tennis Tournament.
Date: April 23, 1961
Duration: 2 minutes 32 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
captions transcript

[News Clip: Art show]

Description: Video footage from the WBAP-TV television station in Fort Worth, Texas, covering a news story about the Fifth Avenue Art Gallery's new exhibition.
Date: April 23, 1961
Duration: 1 minute 13 seconds
Creator: WBAP-TV (Television station : Fort Worth, Tex.)
Partner: UNT Libraries Special Collections
open access

Feasibility Study of a New Mass Flow System : Quarterly Report No. 4 Covering the Period from March 1, 1961 to May 31, 1961

Description: This is the fourth quarterly report that documents a system of mass flow that can record measurements of homogeneous flow, slurries, highly corrosive fluids and multiphase fluids, additionally considering pressure drops, measuring external to the flow, ruggedness and reliability.
Date: June 23, 1961
Creator: Haffner, J. W.; Stone, C. A. & Genthe, William K.
Partner: UNT Libraries Government Documents Department
open access

RADIOISOTOPE AND RADIATION APPLICATIONS QUARTERLY PROGRESS REPORT. SECTION I. USE OF INTRINSIC RADIOACTIVE TRACERS FOR PROCESS CONTROL. SECTION II. RADIATION-INDUCED GRAFT-POLYMERIZATION STUDIES

Description: Research was continued in the areas of intrinsic radioactive tracers for industrial process control and the influence of structural factors in radiation- induced graft polymerization. The use of in-process isotope neutron soarces to produce short-lived radiotraces is discussed. A 10c Po--Be neutron source was obtained for exploratory experiments. The design and construction of a neutronsource storage shield and an activatioa-cell holder are underway. The effect of structural factors oii the eIficiency of free-radical site formation in acrylate and methacrylate polymers was emphasized. Site measurements versus dose were made for poly-n-hexylmethacrylate. Two additional methods for measuring free-radical conceiitrations, a chemical method employing diphenylpicrylhydrazyl and hydroquinone and a method based on molecular-weight decreases, were developed. The grafting studies were continued. (M.C.G.)
Date: October 23, 1961
Creator: McFarling, J.L.; Gluck, P.; Kircher, J.F.; Sunderman, D.N.; Sliemers, F.A.; Luttinger, M. et al.
Partner: UNT Libraries Government Documents Department
open access

THE EFFECTS OF INTERNAL HEAT GENERATION ON POT CALCINATION RATES FOR RADIOACTIVE WASTES

Description: Methods by which the radial deposition mechanism was determined in experiments with simulated waste solutions are reviewed. Based on this mechanism, an expression for the rate of solid deposition with internal heat generation was developed by a combined heat and material balance. A sample calculation for Purex waste showed that a moderate heat generation rate of 5000 Btu/hr/ft/sup 3/ would decrease the time to fill a 12-in.-dia calcination vessel from 78 to 55 hr. For the calcination stage of the process in which the deposited solids are heated in the absence of a liquid phase, a solution was developed for the equation of heat transfer with the temperature profile from the solid deposition stage as an initial condition. For the example Purex waste with a heat generation rate of 5000 Btu/hr ft/sup 3/, less than 15 min would be required for calcination, compared to about 8 hr in experiments with simulated wastes. (auth)
Date: October 23, 1961
Creator: Perona, J.J.
Partner: UNT Libraries Government Documents Department
open access

Calculation of Doppler Coefficient and Other Safety Parameters for a Large Fast Oxide Reactor

Description: Several safety parameters are calculated for a large, fast, Na-cooled, oxide-fueled reactor. The Doppler coefficient is studied as regards its effect on the reactivity during a power excursion, and its dependence on the neutron spectrum, on the concentrations of U/sup 238/, Pu /sup 239/ , a nd Pu/sup 240/, on spatial temperature and power distributions, and on temperature. Other parameters studied include the Na temperature coefficient of reactivity, and the reactivity insertion caused by total Na loss; reactivity coefficients caused by thermal expansion of fuel and steel cladding; the excess operating reactivity; and the reactivity caused by a fuel slump. The effects of a Be reflector on neutron lifetimes are determined. The safety aspects are balanced against economic considerations. (T.F.H.)
Date: March 23, 1961
Creator: Greebler, P.; Hutchins, B. A. & Sueoka, J. R.
Partner: UNT Libraries Government Documents Department
open access

A MODULAR, LOW-COST, SODIUM-HEATED STEAM GENERATOR

Description: A proposed design and development program for a potentially economical, high-performance, sodium-heated steam generator is described. The concept employs modular units grouped together to provide for any combined power level desired. Fabrication expense is shown to be reduced by the reduction in heat transfer area requirements. This reduc, tion is achieved through improved heat transfer coefficients which exist under supercritical steam conditions. The testing of two small units ( approximates 18 Mw total) is shown to be sufficient to verify performance for any size unit because of the modular concept employed. (auth)
Date: October 23, 1961
Partner: UNT Libraries Government Documents Department
Back to Top of Screen