High Pressure Pump Seal Development
Description:
"Test results indicated that graphite is not suitable for seal face material. A program to evaluate various materials and seal face geometries was initiated. A seal run using nucerite-bearium combination was carried on for six hours."
Date:
March 5, 1962
Creator:
Zanoni, P. J.
Item Type:
Refine your search to only