Corrosion of Zircaloy in Crevices under Nucleate Boiling Conditions

Description: Abstract: The MSAR corrosion test loop was used to study the effect of VKE-shaped crevices on the corrosion resistance of Zircaloy under boiling heat-transfer condtions in both ammoniated and lithiated water at pH 10.5.