Reactor Automatic Control and Load Swing Test. Test Results DL-S-144 (T-554924). Section I. Second Performance

Description: The purpose of this test was to determine the controlling ability of the Reactor Power and Temperature Control System and to determine the operational characteristics of the station during load swings after change of operating conditions from 523 F, 2000 psi, to 500 F, 1800 psi. The Reactor Power and Temperature Control System satisfactorily controlled rod movements to maintain all primary plant parameters within their individual limits during steady state operation and during ramp function loa… more
Date: March 25, 1959
Creator: Mafrica, Roces
Partner: UNT Libraries Government Documents Department
open access

Reactor Plant Container Air Cooling System. Section III. Second Performance. Test Results DL-S-136 (T-550090)

Description: The purpose of this test was to determine the performance of the Reactor Plant Container Air Cooling System with four reactor coolant loops at operating temperature. Due to the fact that the test was performed with the chamber door open, no significant conclusion can be arrived at concerning the efficiency of the Air Cool System. The 1B supply fan circulated approximately 20 per cent less air than the 1A fan during the test. Later investigation revealed that the turning vanes above the 1B dampe… more
Date: March 25, 1959
Partner: UNT Libraries Government Documents Department