Primary Plant Control and Instrumentation. Section I. Test Results DL-S-125, T-550079
Description:
The purpose of the test was to determine if the main coolant pump stator and bearing water temperature monitors and the "Primary Coolant Pump Noise Monitors" operate properly. The 1A, 1B and 1C pump bearing water temperature monitors operated satisfactorily. It is believed that the data for the 1D Bearing Water Temperature shown in Table I should be tabulated ad 1D stator temperature. This discrepancy is clarified in the note on Table I. The 1A and 1C pump stator temperature monitors operate s…
more
Date:
July 22, 1958
Creator:
Shramko, John, Jr.
Partner: