An Analysis of the Disturbance of a Uranium Oxide Capsule Surface Temperature Distribution Resulting From a Thermocouple Attached to the Inside Surface
Description:
A study was initiated to determine the precision with which surface temperature measurements could be made in irradiation capsules containing ceramic fuel. A thermocouple was considered to be positioned in a longitudinal groove prepared in the uranium oxide and metallurgically bonded to the inside surface of the stainless steel clad. A fuel capsule having a 3/4 inch outside diameter, designed as a segment of the EGCR fuel element, and operating with a heat generation rating of 27,500 Btu/hr/lin…
more
Date:
November 1, 1961
Creator:
Newell, P. H.
Item Type: