This system will be undergoing maintenance January 21st between 9:00AM and 12:00PM CST.

Search Results

open access

The Anodizing of Zirconium

Description: Five continuous coatings were produced on zirconium coupons using an anodizing technique. These layers appear to be quite adherent and not subject to visible or audible failure caused by flaxion of the basis metal, Their abrasion resistance, though not investigated thoroughly, appears to be moderately good.
Date: November 3, 1953
Creator: Ray, William E.
Partner: UNT Libraries Government Documents Department
open access

Some Comments on the Selection of Operating Temperatures for DPR

Description: The results of this investigation indicate that maximum electric power generation can be obtained by selecting the turbine steam temperature within a range of plus/minus 30 degrees C. from an "idealized" steam temperature. This "idealized" steam temperature is shown to depend primarily on the maximum permissible uranium temperature. The minimum available condenser temperature and the temperature rise of the coolant in the pile effect the selection of the turbine steam temperature to lesser ex… more
Date: November 16, 1953
Creator: Altmann, Manfred.
Partner: UNT Libraries Government Documents Department
open access

Final Report: Production Test No 105-505-SI. Exposure of Two Different Types of Rubber to Pile Water

Description: In connection with different seals for C & D equipment it appears advantageous that many parts could be made of rubber or other elastic polymers. However, data on the deterioration rate of these materials under irradiation are somewhat scant in the available literature. It appears that for neutrons and pure gamma radiation that a good grade of natural rubber stands up best in all the test reported and because the results of the neutron irradiation are so closely correlated with results from g… more
Date: November 18, 1953
Creator: Cooke, J. P.
Partner: UNT Libraries Government Documents Department
open access

Coulometric Determination of Phosphate

Description: The conventional volumetric micro-determination of phosphate depends upon the precipitation of phosphomolybdate, filtration and washing of the precipitate, and titration with standard base. The method is slow and tedious, subject to many interferences, and is not applicable to samples containing less than 1-2 mg of phosphate. Other weak acid anions, such as carbonate or acetate, interfere in the method. Strong acid anions, such as nitrate, sulfate, and chloride do not interfere.
Date: November 19, 1953
Creator: Carson, W. N., Jr. & Gile, H. S.
Partner: UNT Libraries Government Documents Department
open access

The Hydrogen Content of Fabricated Uranium

Description: The hydrogen contents of several types of fabricated uranium have been determined by a vacuum method and expressed in terms of ccH2/ccU. The data indicate that alpha-rolled metal contains about 0.25 ccH2(STP)/ccU whereas beta heat-treated uranium yielded values between 0.30 and 0.37 cc per cc. Restricted efforts were made to determine where in the heat treatment the 5 to 10 cc of hydrogen per slug were taken up. It appears that no one operation is wholly responsible for this additional gas, … more
Date: November 30, 1953
Creator: Ray, W. E. & Bowen, H. C.
Partner: UNT Libraries Government Documents Department
open access

A Comparative Study of Hanford and Utah Range Sheep

Description: Observations on sheep representing flocks in Utah adjacent to the Nevada Proving Ground were compared with findings made on experimental sheep exposed to various amounts of radioiodine. The Utah sheep showed no evidence of the radiation damage observed in experimentally treated sheep. Estimations of amounts of radioiodine on vegetation required to cause serious thyroid damage following a contamination event are included.
Date: November 30, 1953
Creator: Bustad, Leo K.; Marks, S.; Dockum, N. L.; Kalkwarf, D. R. & Korrberg, H. A.
Partner: UNT Libraries Government Documents Department
open access

Plutonium Recycle Test Reactor Final Safeguard Analysis: Supplement 2, Consequences of a Primary Coolant Leak

Description: Review of previous work is presented in addition to the results of recent studies concerning loss of primary coolant when the system is cold and pressurized and the problem of supplying adequate cooling following the injection of light water.
Date: November 15, 1960
Creator: Wittenbrock, N. G. & Muraoka, J.
Partner: UNT Libraries Government Documents Department
open access

The Thermal Hydraulics Laboratory at Hanford

Description: Report describing the experimental facilities of Hanford's Thermal Hydraulics Laboratory, its equipment, personnel, operating schedules, and safety procedures. Appendix begins on page 49.
Date: November 1961
Creator: Batch, J. M.; Toyoda, K. G. & Hanthorn, H. E.
Partner: UNT Libraries Government Documents Department
open access

Plating Thickness Tester

Description: An electromagnetic eddy current instrument is described that is capable of measuring copper and nickel plating 1 to 8 mils thick plated on bismuth mandrils of various sizes and shapes.
Date: November 15, 1957
Creator: Fitch, C. E., Jr.
Partner: UNT Libraries Government Documents Department
Back to Top of Screen