14-Inch Swing Check Valve Test
Description:
The check valve for the Hallam Power Reactor uses a knife-edge bearing for the flapper in place of the usual journal-type bearing. Mechanical cycling in sodium at 600 deg F was used to check operation of this bearing. A total of 309 mechanical cycles was completed with no apparent malfunctioning of the valve. Measured leskage rates were 0.46 gpm at 0.93 psig, 0.73 gpm at 3.4 psig. and 0.32 gpm at 5.9 psig. (M.C.G.)
Date:
February 10, 1960
Creator:
Cygan, R.
Partner:
UNT Libraries Government Documents Department