Transformation and Magnetic Phenomena Occuring in Boron Stainless Steel Vertical Safety Rods

Description: Summary: "The low carbon 18-8 stainless steels containing approximately 1.7 per cent boron used for vertical safety rods at Hanford were found to be structurally stable in the temperature range 0-450 C. The addition of boron decreases the stability of this metastable austenitic alloy. Sufficient ferrite formation is induced by sub-zero temperature treatments to result in dimensional changes and a magnetic alloy. The difficulties encountered in machining this material are believed to be due prim… more
Date: February 6, 1953
Creator: Hueschen, R. E.
Partner: UNT Libraries Government Documents Department
open access

Flow Decay After an Electrical Power Outage in the PRTR

Description: Previously, W. S. Figg and T. W. Ambrose (HW-51767 Rev) have investigated the problem of flow decay following electrical power loss to the PRTR primary coolant pumps. However, since the time of their study many reactor piping changes have been made in the design; therefore, it has become advisable to re-examine the problem incorporating these changes.
Date: February 6, 1959
Creator: Muraoka, J.
Partner: UNT Libraries Government Documents Department