Description of a capsule for irradiation of fuel specimens at high temperatures
Description:
A controlled-temperature irradiation capsule was operated containing small fueled specimens at 160O to 1650 F. The design involved calculating the specimen heat-generation rate and designing an insulating gas gap around the specimens to achieve the desired temperature. Electric heaters were inserted to help control temperature. The thickness and composition of the gas gap were modified prior to operation on the basis of information on probable neutron flux obtained from a nuclear mock-ups and o…
more
Date:
April 22, 1959
Creator:
Basham, S. J.; Stang, J. H.; Goldthwaite, W. H. & Dunnington, B. W.