Confinement of airborne radioactivity. Final progress report, January-December 1978
Description:
A new test method has been developed at the Savannah River Laboratory for evaluating the iodine retention capabilities of carbon used in the airborne-activity confinement system. Methyl iodide tagged with I-131 is injected into a test gas stream continuously for 5 hours with test conditions of 80/sup 0/C temperature, 95% relative humidity, and 55 feet per minute linear flow velocity. Results show that the CH/sub 3/I retention efficiency is independent of the inlet CH/sub 3/I concentration over …