Engineering study: Fast Flux Test Facility fuel reprocessing
Description:
Several alternatives were studied for reprocessing FFTF fuels at Hanford. Alternative I would be to decontaminate and trim the fuel at T Plant and electrolytically dissolve the fuel at Purex. Alternative II would be to decontaminate and shear leach the fuels in a new facility near Purex. Alternative III would be to decontaminate and store fuel elements indefinitely at T Plant for subsequent offsite shipment. Alternative I, 8 to 10 M$ and 13 quarter-years; for Alternative II, 24 to 28 M$ and 20 …
more
Date:
January 7, 1974
Creator:
Beary, M. M.; Raab, G. J.; Reynolds, W. R., Jr. & Yoder, R. A.
Partner: